Airflow AV 100 User Manual Download Page 2

 

 

with timer 

DESTINATION 

 

The in-line mixed flow fans with channels' diameters ranging from 100 to 150 mm are 
designed for installation in the ventilating systems that require high pressure, powerful 
air flow.  

The pumped air should not contain dust and other solid admixtures, as well as sticky 
substances and fibrous materials, the temperature of the transferred air must not exceed 
+45°C. Fans are installed horizontally vertically and can be used both for exhaust and for 
blowing ventilation. The fans are manufactured as two-speed ones and are designed for 
long-term operation without switching off mains.  

By the type of protection against electrical shock the fans belong to Class II.  

The degree of protection against access to the hazardous parts and water intrusions 
is IPX4.  

Design 

of the fans is being constantly perfected, so some models could differ from other ones ‘ 

described in this certificate 
 

THE BASIC TECHNICAL DATA 

 

The fans' designations, their parameters, connective and mounting dimensions are 
provided in fig 2-3. Fans are intended for connection to 230V AC, 50 Hz. 

 An external 3A 

fuse is required for each fan unit. 

It is permitted to use the fan under ambient air temperature 

from +5

o

C to +40

o

C

 

 
  

The scheme of designation of fans. 

 

 

 

 

AV 

X      X 

 

 

 
 
 
 
 
 
 

 

 

 

 

 

 

 

 
 

Notes. 

 

The diameter of the air duct should match with the diameter of fan delivery pipe

 

 

Summary of Contents for AV 100

Page 1: ...90411215 Issue5 07 13 USERS MANUAL IN LINE MIXED FLOW ...

Page 2: ...operation without switching off mains By the type of protection against electrical shock the fans belong to Class II The degree of protection against access to the hazardous parts and water intrusions is IPX4 Design of the fans is being constantly perfected so some models could differ from other ones described in this certificate THE BASIC TECHNICAL DATA The fans designations their parameters conn...

Page 3: ...3 R P M Consumption current A Power W Launching capacity мF Noise level dBA 3 m Voltage V 50Hz Connection layout AV 100 145 187 2180 2385 0 11 0 21 21 33 27 36 1 230 Fig 2 3 AV 125 220 280 1950 2455 0 18 0 27 23 37 28 37 1 230 Fig 2 3 AV 150 405 520 1680 2460 0 17 0 27 30 60 4 33 34 1 230 Fig 2 3 Type Sizes mm Weight kg D D1 H B L AV 100 96 126 190 165 246 1 5 AV 125 123 136 190 165 246 1 4 AV 150...

Page 4: ...ed to connection of fans to the mains and adjustment of the timer turn off delay time are to be carried only if the mains voltage is switched off RECOMMENDATIONS For horizontal installation of the fan place an air duct with the length of not less than 1m on the suction side for vertical installation of the fan it is necessary to place a valve grille at the suction duct end Connection of the fans i...

Page 5: ...outs of the fan to the stationary wiring are shown on figs 2 3 In case of one speed operation at one speed it is necessary to connect the wire L of the mains to one of the terminals corresponding to the s elected rotation speed LH maximum speed LL minimum speed Speed of the fan is switched using external switch S1 Fan with timer T fig 3 ensures automatic turning off the fan after certain time from...

Page 6: ...Fig 2 Wiring Diagram AV100 AV125 and AV150 ...

Page 7: ......

Page 8: ...y fan s malfunction occurs during the warranty period through the fault of manufacturer the respective customer shall be entitled to replacement of the fan at the manufacturer s location Airflow Developments Limited Aidelle House Lancaster Road Cressex Business Park High Wycombe Bucks H12 3QP E mail info airflow com Telephone 44 0 1494 525252 Facsimile 44 0 1494 461073 Web airflow com THE ACCEPTAN...

Reviews: