1.13 Accessories
Please see below a list of compatible accessories for MultiPlexBox units.
ECO Element Controller - 90001253
Manual 4 level operation or automatic mode.
Touch Element Controller - 90001254
Manual 4 level operation, automatic mode, or weekly programme.
Connection Plate - 90001252
For suspended installation and suitable for concrete.
Connection set - 90001247
For connection of MultiPlexBox to the connection plate. Set consists of 12 individual connectors and mounting
brackets.
Hu VOC Sensor - 90001249
For measuring the mixed gas concentration (VOC) and relative humidity.
Humidity sensor - 90001248
For measuring the relative humidity.
Duct Support Set 7 (7 pipes) - 90001250
For single-sided or double-sided connection of Airflex Pro.
Duct Support Set 13 (13 pipes) - 90001251
For single-sided or double-sided connection of Airflex Pro.
When using more than 61 l/s (219.6m3/h) of air, increased flow noise may occur. It should be checked whether
a corresponding silencer must be provided on site. Existing fire protection regulations must be observed.
2 . I n s t a l l a t i o n
2.0 Assembly
The unit is designed for installation in internal rooms, onto walls or ceilings. The room temperature must lie
above 5 °C.
Narrow duct bends result in increased pressure losses and noise pollution. The ventilation pipes
must never be kinked. Ensure the fixed and tight fastening of the connectors. The unit cover must be freely
accessible for maintenance and installation
work. Please ensure you reference the domestic compliance
guide for proper duct installation.
2.1 Ducting installation
When designing the ductwork, use the shortest possible runs. Supply and extract air rooms must be defined
in advance. Extractor hoods must not be connected to the system. Sufficient overflow openings (door gap,
door grilles) as per building regulations are to be provided to ensure air circulation within the room. Shorten
the duct parallel to the rings. To avoid leaks, the pipe must not be cut at an angle. The MultiPlexBox is
prepared for the connection of 125 mm pipes on the inlet side. The supply air and extract air ducts in the
rooms are designed with 75mm Airflex Pro round pipe. The outlet side connections are also 125mm for the
125/125 Straight through version. The connectors are provided with dust covers. These must be broken out
for the connection of air pipes.
2.2 General Installation
WARNING: Isolate the unit from the mains power supply before any installation
work or opening the terminal compartment! The electrical connection must only be
carried out by a qualified electrician in accordance with the relevant wiring
diagram. Existing fire protection regulations must be observed!
WARNING: An electric shock can result in death or serious injury.
Isolate the unit from the mains power supply before working on the unit!
Mains connection is provided via a plug connection. Mains connection must be
provided with a cable cross section of 3 x 1 mm² or 3 x 1.5 mm² on site.