AirCycler® g2-k
Installation Testing Guide
®
Ventilation Products
Testing the
AirCycler® g2-k
completed installation is an easy
two step process:
STEP 1
Test the FanConnect
(tm)
connection & operation
STEP 2
Test thermostat, damper and furnace connection and
operation
STEP
1
a. With the thermostat off, turn on the
FanConnect
switch.
b. Confirm the exhaust fan is running.
c. The
AirCycler
®
g2
display should show the
Exhaust fan is on and the OA damper is open.
d. Confirm the OA damper is open.
e. Turn off exhaust fan.
PERCENTAGE OF
VENTILATION COMPLETE
EXH - EXHAUST
FAN IS ON
OA - FRESH AIR
DAMPER IS OPEN
LCD DISPLAY
a. Make sure exhaust fan is off.
b. Turn thermostat FAN switch to ON.
c. Confirm
AirCycler
®
g2
display show’s FAN and OA
damper open.
d. Confirm furnace fan is running.
e. Remover
AirCycler
®
g2
from it’s base. Furnace fan
should shut off..
f. DONE! Replace
AirCycler
®
g2
controller on it’s base.
STEP
2
LCD DISPLAY
OA - FRESH AIR
DAMPER IS OPEN
PERCENTAGE OF
VENTILATION COMPLETE
FAN ON FROM
THERMOSTAT
See reverse for troubleshooting tips and frequently asked questions
NOTE: When using in SLAVE mode you will also see the EXH icon illuminated.