Manual No. BLWR047

Rev. 1  February 2015

oPerAtinG mAnUAl

moDelS: cVF-8X220 AnD SVF-10X220

PortABle FAnS For HAZArDoUS locAtionS

II 2 G c

Ex d IIB T6 Gb

ITS 14 ATEX 17992X

 

IECEx ETL 14.0010X

Ex d IIB T6 Gb

0359

Summary of Contents for CVF-12EX22

Page 1: ...Free 1 800 866 8100 Fax No 757 424 5348 http www airsystems com e mail sales airsystems com Manual No BLWR047 Rev 1 February 2015 OPERATING MANUAL MODELS CVF 8X220 AND SVF 10X220 PORTABLE FANS FOR HAZ...

Page 2: ...external grounding lugs Model SVF 10X220 contains the same components except the blower housing is made of steel The units have beeen tested by Intertek and assigned ATEX and IECEx certification numb...

Page 3: ...and determine the reason for motor overheating Check to make sure that 1 the proper extension cord gauge is used 2 check the blower intake for debris that may be clogging the air inlet or causing the...

Page 4: ...tion NO OTHER WARRANTY EXPRESSED OR IMPLIED AS TO DESCRIPTION QUALITY MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER MATTER IS GIVEN BY AIR SYSTEMS IN CONNECTION HERE WITH UNDER NO CIRC...

Page 5: ...le Vent STEP 4 Install universal mount on Saddle Vent and set in place with manhole lid for support STEP 5 Install duct from blower to 90 elbow STEP 6 Turn on blower or fan Warning For explosive envir...

Page 6: ...tested continuously during confined space occupancy to ensure a sta ble atmosphere and worker safety as atmospheric conditions can change rapidly Additional procedures and recommendations are availab...

Page 7: ...ce ohms does not exceed 750k If sufficient resistance is not achieved the duct should be removed from service STEP 4 The ON OFF switch is integrated in the motor Pull the ON OFF switch knob outward to...

Page 8: ...t of magnesium titanium and zirconium SPECIAL CONDITION OF SAFE USE User specified ATEX approved plug to meet hazardous location requirement KILLARK part no ELAP15232 Item 23 ground lug manufacturer p...

Page 9: ...H P N 5308921 1 13 ELA007 1 2 CONDUIT LOCK NUT ZINC COATED STEEL 1 16 MTR043EX22 ATEX APPROVED MOTOR 220 230 VAC 50 HZ 1 17 HDWR068 COUPLING NUT 10 24 X 3 4 LONG GRADE 2 1 18 FS1032X050 10 32 X 5 ROUN...

Page 10: ...5 total content of magnesium titanium and zirconium SPECIAL CONDITION OF SAFE USE User specified ATEX approved plug to meet hazardous location requirement KILLARK part no ELAP15232 Item 23 ground lug...

Page 11: ...0 24 X 3 4 LONG GRADE 2 STEEL 1 9 FS10X5 8TH 10 X 5 8 TRUSS HEAD PHILLIPS SCREW STEEL 2 10 ELA051 ALUMINUM GROUNDING LUG 6 14 AWG 6 35mm MAX 2 11 ELA007 1 2 CONDUIT LOCK NUT ZINC COATED STEEL 1 12 MBK...

Page 12: ...TER EXPLOSION PROOF PLUG FOR HAZARDOUS LOCATIONS CVF CND6 Conductive Duct Canister with 6 Ft 183 cm of Conductive Duct CVF CND15 Conductive Duct Canister with 15 Ft 457 cm of Conductive Duct CVF CND25...

Page 13: ...nt Conductive Duct Canister with 6 of Conductive Duct Conductive 90 Elbow Universal Mount 6 and 15 of Conductive Duct Conductive Saddle Vent Duct Canister Conductive 90 Elbow Universal Mount SVF 10X22...

Page 14: ...Hazardous Location Explosive Atmospheres Guide to Equipment Certification Requirements 14...

Page 15: ...15 EXAMINATION CERTIFICATE...

Page 16: ...per Crescent Chesapeake Va 23320 Telephone 757 424 3967 Toll Free 1 800 866 8100 Fax No 757 424 5348 http www airsystems com e mail sales airsystems com Printed in the U S A Copyright Air Systems Inte...