SB-101
Panic Button
User Manual
Page 1: ...SB 101 Panic Button User Manual ...
Page 2: ...effort to ensure the accuracy of the information in this user s guide However we are not liable for the inaccuracies or errors in this guide Please use with caution All information is subject to change without notice This product contains some codes from GPL In compliance with GPL agreement AirLive will publish the GPL codes on our website Please go to www airlive com and go to the Support GPL men...
Page 3: ...let on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired opera...
Page 4: ...dd to Z WaveTM Network 2 1 2 Function Control 3 1 3 Z WaveTM Notification 3 1 4 Z WaveTM Message Report 4 1 5 Activate the power 4 1 6 Over The Air OTA Firmware Update 5 1 7 Security Network 5 1 8 Z Wave Configuration Settings 5 1 9 Z Wave Supported Command Class 6 1 10 Specifications 7 ...
Page 5: ......
Page 6: ...cs devices and systems such as lighting home access control entertainment systems and household appliances This product can be included and operated in any Z WaveTM network with other Z WaveTM certified devices from other manufacturers and or other applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network The de...
Page 7: ... press the top right key four times within 1 5 seconds and do not release the top right key in the 4th pressed and the LED will light ON 2 After 3 seconds the LED will turn OFF after that within 2 seconds release the keys If successful the LED will light ON one second Otherwise the LED will flash once 3 IDs are removed and all settings will reset tofactory default Association 1 Have Z WaveTM Contr...
Page 8: ...l Set V4 Key Left Command 0x0003 Universal Label Volume Up Key Right Command 0x0002 Universal Label Volume Down 1 2 2 Lighting Group Control Only has one group button which controls two lighting groups Lighting Group Control Left Key Right Key Lighting group 1 Association group 2 Lighting group 2 Association group 3 Notice For switch AV control or lighting group control function please setting the...
Page 9: ...level is too low every 30 minutes will report once Notice The configuration NO 10 could be setting to zero to disable the auto report 1 5 Activate the power The device can not work normally in the first time Please activate the battery through micro USB before the first use After the device is activated by connecting to micro USB the device will start charging and LED will light on with red color ...
Page 10: ...on Do not running the OTA when the battery is running low 1 7 Security Network The device supports the security function When the device included with a security controller the device will auto switch to the security mode In the security mode the follow commands need using Security CC wrapped to communicate otherwise it will not response COMMAND_CLASS_BATTERY COMMAND_CLASS_SIMPLE_AV_CONTROL_V1 COM...
Page 11: ...et Level 0 All Setting the BASIC command value to turn on the light in the association group 2 0 means using the value of configuration 2 to set 83 Association Group 3 Basic Set Level 0 Setting the BASIC command value to turn on the light in the association group 3 0 means using the value of configuration 2 to set 1 9 Z Wave Supported Command Class COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BAT...
Page 12: ...22 927 MHz JP TW 921 40 MHz 919 80 MHz ANZ 869 00 MHz RU 865 20 MHz IN 916 00 MHz IL Range Minimum 40 meters indoor 100 meters outdoor line of sight Operating Temperature 0 40 For indoor use only Specifications subject to change without notice due to continuing product improvement OvisLink Corp http www airlive com TEL 886 2 2218 6888 FAX 886 2 2918 6988 ...