Air King AK922 Specifications Download Page 1

SPECIFICATIONS

EXHAUST FANS

AK922

Bulb Heat Lamp

120 Volts, 4.0 amps, 60 hz.

Grill

White, polymeric grill (flame retardant ABS UL rated 94-5V)
secured in place with torsion springs; easily removed if
neccessary, dimensions - 16

1/2

" x 10".

• Heater Housing

23 gauge painted steel housing. Dimensions 13

7/8

" x 8" x 5

7/8

".

• Lamping Information

2 - 250 watt maximum, type R40 bulb, medium base, 1700 Btu.

• Duct Collar

Plastic collar for 4" duct connection, comes complete with built
in non-metallic back draft damper for quiet operation.

• Unit Mounting

The housing will mount in ceilings with at least 6" of clearance
and through drywall thickness up to 

3/4

", with a rough-in opening

of 13

7/8

" x 8". Rated for ceilings insulated to R-40. The housing

will mount between 16" on center joists, using the 4 supplied
housing mounting rails.

• Single Pack Shipping Info

Box Dim: 12

1/2

" x 16

3/4

" x 8"

UPC: 0-8316227031-3
Shipping Weight: 8 lbs.

CUL - TYPE IC RATED

Canada:

 110 Glidden Road

Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015

U.S.:

 820 Lincoln Drive

West Chester, Pennsylvania  19380-4466
Tel: (877)-304-3785
Fax: (610) 696-8048

Updated 1-06

Specifications subject to change without notice.

C

US