SPECIFICATIONS
Motor .................................120V, 60 Hz
Blade diameter ...................20" ( 50.8 cm)
Speeds ...............................3
Control................................Rotary Switch
Air flow distribution .............120°
Approvals............................UL Listed. Close mesh fan guard
meets OSHA requirements.
DESCRIPTION
The Air King 20" (50.8 cm) Deluxe Pivot Fan features 3 speed whis-
per-quiet operation, a 5-paddle fan blade, and 120° adjustable tilt.
The fan has a permanently lubricated motor with a 6 ft. (1.8 m) 18/3
cord set.
MODEL 4CH68G/9500G
SPEED HIGH MED LOW
CFM 2470 2055 1570
M
3
/s 1.17 0.97 0.74
RPM 1137 1018 777
Amps 1.05 0.82 0.62
Watts 129 106 79
dB A 64 60 52
GENERAL SAFETY INFORMATION
When using electrical appliances, basic
precautions should always be followed to
reduce the risk of fire, electric shock and injury
to person, including the following:
1. Read all instructions before using Fan.
2. Make certain that the power source conforms to the electrical
requirements of the Fan.
3. Use this Fan only as described in this manual. Any other use
not recommended by the manufacturer may cause fire, electrical
shock, or injury to persons.
4. Unplug power cord before installing, servicing, or moving the Fan.
WARNING:
DO NOT DEPEND UPON THE ON-OFF SWITCH AS
THE SOLE MEANS OF DISCONNECTING POWER WHEN
INSTALLING OR SERVICING THE FAN. ALWAYS UNPLUG THE
POWER CORD.
5. This Fan must NOT be used in potentially dangerous
locations such as flammable, explosive, chemical-laden
or wet atmospheres.
6. DO NOT use Fan in or near a window. Rain may create an
electrical hazard.
7. The power cord is equipped with a three-prong grounded plug
that must be inserted into a matching receptacle. Under no
circumstances must the grounding prong be cut off the plug.
Where a two-prong wall receptacle is encountered, it must be
replaced with a properly grounded three-prong receptacle installed
in accordance with the National Electrical Code (NEC) and all
applicable local codes and ordinances. This work must be done
only by a qualified electrician, using copper wire only.
WARNING:
USE OF A THREE-PRONG TO TWO-PRONG
ADAPTER IS NOT RECOMMENDED. IMPROPER
CONNECTION MAY CREATE THE RISK OF ELECTRO-
CUTION. USE OF SUCH ADAPTERS IS NOT PERMITTED
IN CANADA.
WARNING:
THIS PLUG IS A SAFETY FEATURE. TO
REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
PERSONAL INJURY, DO NOT REMOVE, REPLACE, REPAIR
OR TAMPER WITH THE ORIGINALLY SUPPLIED PLUG. IF
THE FAN DOES NOT FUNCTION PROPERLY, IT MAY BE
DUE TO THE SAFETY DEVICE INCORPORATED IN THIS
PLUG. CONTACT YOUR GRAINGER DISTRIBUTOR.
8. Where possible, avoid the use of extension cords. If they must
be used, minimize the risk of overheating by ensuring that they
are UL listed. Never use a single extension cord to operate more
than one Fan.
9. Do not operate any Fan with a damaged cord or plug or after the
Fan malfunctions, has been dropped or damaged in any manner.
Return Fan to authorized service facility for examination, electrical
or mechanical adjustment or repair.
10.Do not insert or allow fingers or foreign objects to enter any
ventilation or exhaust opening as it may cause an electric shock
or fire, or damage the Fan. Do not block or tamper with the Fan
in any manner while it is in operation.
11.Always place the Fan on a stable, flat, level surface when operating,
to avoid the chance of the Fan overturning. Locate the Power Cord
so the Fan or other objects are not resting on it. Do not run Power
Cord under carpeting. Do not cover Power Cord with throw rugs,
runners, or the like. Arrange Power Cord away from room traffic
and where it will not be tripped over.
12.This Fan is not intended for use in wet or damp locations. Never
locate a Fan where it may fall into a bathtub or other water container.
13. Do not use Fan outdoors.
14.This Fan is not suitable for use in agricultural facilities including
areas where livestock, poultry or other animals are confined.
Please refer to National Electric Code (NEC) Article 547-7 (2002),
or applicable state or local codes or standards relating to electrical
requirements for Agricultural Buildings.
THIS FAN DOES NOT
MEET THE REQUIRMENTS OF NEC ARTICLE 547-7 (2002).
15.This Fan is not suitable for use in hazardous locations. Please refer to
National Electric Code (NEC) Article 500 or applicable state or local
codes or standards relating to electrical requirements for Hazardous
locations.
THIS FAN DOES NOT MEET THE REQUIRMENTS OF
NEC ARTICLES 500 (2002)
WARNING:
REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
– DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED
CONTROL DEVICES.
SAVE THESE
INSTRUCTIONS
This Fan is not intended to be used in
commercial, industrial or agricultural settings.
MODEL /MODELO/ MODÉLE 4CH68G/9500G