background image

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT 

DESCRIBED.  PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.  FAILURE TO COMPLY 

WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

 RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.  

1

2084007

Rev. P 6/07

20" DELUXE PIVOT FAN

MODEL 4CH68G/9500G

OPERATING INSTRUCTIONS & PARTS MANUAL

8

2084007

Rev. P 6/07

SPECIFICATIONS

Motor  .................................120V, 60 Hz

Blade diameter ...................20" ( 50.8 cm)

Speeds ...............................3

Control................................Rotary Switch

Air flow distribution .............120°

Approvals............................UL Listed. Close mesh fan guard 

                                            meets OSHA requirements.

DESCRIPTION

The Air King 20" (50.8 cm) Deluxe Pivot Fan features 3 speed whis-

per-quiet  operation,  a  5-paddle  fan  blade,  and  120°  adjustable  tilt.  

The fan has a permanently lubricated motor with a 6 ft. (1.8 m) 18/3 

cord set.

   

MODEL            4CH68G/9500G

    SPEED    HIGH         MED          LOW

     CFM        2470           2055          1570
     M

3

/s         1.17            0.97           0.74

     RPM        1137           1018          777
     Amps       1.05            0.82           0.62     
     Watts       129             106            79
     dB A         64              60              52

GENERAL SAFETY INFORMATION

When  using  electrical  appliances,  basic 

precautions  should  always  be  followed  to 

reduce the risk of fire, electric shock and injury 

to person, including the following:

1.  Read all instructions before using Fan.  

2.  Make certain that the power source conforms to the electrical 

requirements of the Fan.

3.  Use this Fan only as described in this manual.  Any other use 

not recommended by the manufacturer may cause fire, electrical 

shock, or injury to persons.

4.  Unplug power cord before installing, servicing, or moving the Fan.

WARNING:

 

DO NOT DEPEND UPON THE ON-OFF SWITCH AS 

THE  SOLE  MEANS  OF  DISCONNECTING  POWER  WHEN 

INSTALLING OR SERVICING THE FAN.  ALWAYS UNPLUG THE 

POWER CORD.

5.  This  Fan  must  NOT  be  used  in  potentially  dangerous 

locations  such  as  flammable,  explosive,  chemical-laden 

or wet atmospheres.

6.  DO  NOT  use  Fan  in or near a window.  Rain may create an 

electrical hazard.

7.  The power cord is equipped with a three-prong grounded plug 

that must be inserted into a matching receptacle.  Under no 

circumstances  must  the  grounding  prong  be  cut  off  the  plug.  

Where a two-prong wall receptacle is encountered, it must be 

replaced with a properly grounded three-prong receptacle installed 

in accordance with the National Electrical Code (NEC) and all 

applicable local codes and ordinances.  This work must be done 

only by a qualified electrician, using copper wire only.

WARNING:

 USE OF A THREE-PRONG TO TWO-PRONG 

ADAPTER  IS  NOT  RECOMMENDED.    IMPROPER 

CONNECTION  MAY  CREATE THE  RISK  OF  ELECTRO-

CUTION.  USE OF SUCH ADAPTERS IS NOT PERMITTED 

IN CANADA.

WARNING:

 THIS  PLUG  IS  A  SAFETY  FEATURE. TO 

REDUCE THE  RISK  OF  FIRE,  ELECTRIC  SHOCK  AND 
PERSONAL INJURY, DO NOT REMOVE, REPLACE, REPAIR 
OR TAMPER WITH THE ORIGINALLY SUPPLIED PLUG. IF 
THE FAN DOES NOT FUNCTION PROPERLY, IT MAY BE 
DUE TO THE  SAFETY  DEVICE  INCORPORATED  IN THIS 
PLUG. CONTACT YOUR GRAINGER DISTRIBUTOR.

8.  Where possible, avoid the use of extension cords.  If they must       

be used, minimize the risk of overheating by ensuring that they 

are UL listed.  Never use a single extension cord to operate more 

than one Fan.

9.  Do not operate any Fan with a damaged cord or plug or after the 

Fan malfunctions, has been dropped or damaged in any manner.  

Return Fan to authorized service facility for examination, electrical 

or mechanical adjustment or repair.

10.Do  not  insert  or  allow  fingers  or  foreign  objects  to  enter  any 

ventilation or exhaust opening as it may cause an electric shock 

or fire, or damage the Fan.  Do not block or tamper with the Fan 

in any manner while it is in operation. 

11.Always place the Fan on a stable, flat, level surface when operating, 

to avoid the chance of the Fan overturning.  Locate the Power Cord 

so the Fan or other objects are not resting on it.  Do not run Power 

Cord under carpeting.  Do not cover Power Cord with throw rugs, 

runners, or the like.  Arrange Power Cord away from room traffic 

and where it will not be tripped over.

12.This Fan is not intended for use in wet or damp locations.  Never 

locate a Fan where it may fall into a bathtub or other water container.

13. Do not use Fan outdoors.
14.This Fan is not suitable for use in agricultural facilities including 

areas  where  livestock,  poultry  or  other  animals  are  confined. 
Please refer to National Electric Code (NEC) Article 547-7 (2002), 
or applicable state or local codes or standards relating to electrical 
requirements  for  Agricultural  Buildings. 

THIS  FAN  DOES  NOT 

MEET THE REQUIRMENTS OF NEC ARTICLE 547-7 (2002).

15.This Fan is not suitable for use in hazardous locations. Please refer to 

National Electric Code (NEC) Article 500 or applicable state or local 
codes or standards relating to electrical requirements for Hazardous 
locations. 

THIS FAN DOES NOT MEET THE REQUIRMENTS OF 

NEC ARTICLES 500 (2002)

WARNING:

 REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK 

–  DO  NOT  USE THIS  FAN WITH  ANY  SOLID  STATE  SPEED 

CONTROL DEVICES.

SAVE THESE 

INSTRUCTIONS

This Fan is not intended to be used in 

commercial, industrial or agricultural settings.

MODEL /MODELO/ MODÉLE   4CH68G/9500G

Reviews: