Air King 2EJR6G Operating Instructions And Parts Manual Download Page 1

OPERATING INSTRUCTIONS & PARTS MANUAL

16" REVERSIBLE WINDOW FAN
16" (40,64 cm)

 

Model

 

2EJR6G/9155G

Motor ...................................................................... 120V, 60 Hz
Blade size .............................................................. 16" (40,6 cm)
Speeds ................................................................... 3 intake, 3 exhaust
Control ................................................................... Rotary switch
Approvals ................................ ETL Listed. Close mesh fan guard
meets OSHA requirements.

Specifications

Description

  

The Air King

®

 window fan features three intake and three exhaust 

speeds and fits windows 26 1/2" (67,3 cm) to 34 1/2" (87,6 cm) wide 
to 22" (55,9 cm) high.  The adjustable side panels are designed to 
accommodate fan mounting either inside or outside interior window 
trim.  The 16" (40,64 cm), 3-paddle fan blade is driven by a perma-
nently prelubricated motor, 6 foot (1,8 m), 18/3 cord set.

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.  PROTECT YOURSELF 

AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.  FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY 

AND/OR PROPERTY DAMAGE!  RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

Rev. E 2/08

1

2082048A

GENERAL SAFETY INFORMATION

When  using  electrical  appliances,  basic  precautions 

should always be followed to reduce the risk of fire, electric 

shock and injury to person, including the following:

1.  Read all instructions before using Fan.  

2.   Make certain that the room is equipped with a working smoke detector.

3.  Use this Fan only as described in this manual.  Any other use not 

recommended by the manufacturer may cause fire, electrical shock, 

or injury to persons.

4.  To reduce the risk of personal injury and electric shock, the Fan 

should not be played with or placed where small children can reach it.

WARNING:

 

DO NOT DEPEND UPON THE ON-OFF SWITCH AS 

THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALL

ING OR SERVICING THE FAN.  ALWAYS UNPLUG THE POWER 

CORD.

5.  Unplug  power  cord  before  installing,  servicing,  or  moving  the 

Fan.

6.  This Fan must 

NOT

 be used in potentially dangerous locations such 

as flammable, explosive, chemical-laden or wet atmospheres where 

gasoline, paint or flammable liquids are used or stored.

7.  The power cord is equipped with a three-prong grounded plug 

that must be inserted into a matching receptacle. Under no 

circumstances must the grounding prong be cut off the plug.  

Where a two-prong wall receptacle is encountered, it must be replaced 

with a properly grounded three-prong receptacle installed in 

accordance with the National Electrical Code (NEC) and all 

applicable local codes and ordinances.  This work must be done 

only by a qualified electrician, using copper wire only.

WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER 

IS NOT RECOMMENDED.  IMPROPER CONNECTION MAY CREATE 

THE RISK OF ELECTROCUTION.  USE OF SUCH ADAPTERS IS NOT 

PERMITTED IN CANADA.

WARNING: THIS PLUG IS A SAFETY FEATURE. TO REDUCE THE 

RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY, DO NOT 

REMOVE, REPLACE, REPAIR OR TAMPER WITH THE ORIGINALLY 

SUPPLIED PLUG. IF THE FAN DOES NOT FUNCTION PROPERLY, 

IT MAY BE DUE TO THE SAFETY DEVICE INCORPORATED IN THIS 

PLUG. 

8.   This Fan is rated for use as a Window Fan, however, we recommend 

that during rain, this Fan be removed from the window.

9.  Where possible, avoid the use of extension cords.  If they must be 

used, minimize the risk of overheating by ensuring that they are 

UL listed.  

NEVER

 use a single extension cord to operate more 

than one Fan.

10. 

DO NOT

 operate any Fan with a damaged cord or plug or after the 

Fan malfunctions, has been dropped or damaged in any manner.  

Return Fan to authorized service facility for examination, electrical 

or mechanical adjustment or repair.

11.

DO  NOT

  insert  or  allow  fingers  or  foreign  objects  to  enter  any 

ventilation or exhaust opening as it may cause an electric shock 

or fire, or damage the Fan.  

DO NOT

 block or tamper with the Fan 

in any manner while it is in operation. 

12.This  Fan  is  not  intended  for  use  in  wet  or  damp  locations.  

Never locate a Fan where it may fall into a bathtub or other water 

container.

13. 

DO NOT

 use Fan outdoors.

14.This Fan is not suitable for use in agricultural facilities including 

areas  where  livestock,  poultry  or  other  animals  are  confined. 
Please refer to National Electric Code (NEC) Article 547-7 (2008), 
or applicable state or local codes or standards relating to electrical 
requirements for Agricultural Buildings. 

THIS FAN DOES NOT MEET 

THE REQUIREMENTS OF NEC ARTICLE 547-7 (2008).

15.This Fan is not suitable for use in hazardous locations. Please refer to 

National Electric Code (NEC) Article 500 or applicable state or local 
codes or standards relating to electrical requirements for Hazardous 
locations. 

THIS FAN DOES NOT MEET THE REQUIREMENTS OF 

NEC ARTICLE 500 (2008).

WARNING:

 

REDUCE  THE  RISK  OF  FIRE  OR  ELECTRIC 

SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE 
SPEED CONTROL DEVICES.

SAVE THESE INSTRUCTIONS

Rev. E 2/08

8

2082048A

 MODEL/MODELO 2EJR6G/9155G

 NOTES/NOTAS

 

MODEL    2ERJ6G/9155G   

  SPEED   HIGH  MED 

LOW

  CFM  

2470 

1700 

1360

  M

3

/s  

1.17 

0.80 

0.64

  RPM  

1480 

1110 

820

  Amps   0.80 

0.63 

0.50

  Watts     90 

  76 

  61

  dB A 

  64 

  50 

  47

Reviews: