Troubleshooting

PROBLEM: 

Power Light is OFF 

  

POSSIBLE CAUSES

a. Unit is not plugged in 
b. No power at outlet

POSSIBLE SOLUTIONS 

a. Plug in power cable 
b. Check circuits, fuses, 
try a different outlet 
c. Press the POWER button to turn
the power on.

PROBLEM: 

Weak or No mist output

POSSIBLE CAUSES

a. No water in tank 
b. Unit is not leveled
c. White Dust on Nebulizer and/or 
Water Sensor
d. Blower not operating
e. Water temperature  
too low
f. Nebulizer not operating

POSSIBLE SOLUTIONS 

a. Fill tank with water and wait 10 – 15 minutes 
b. Place unit on level surface.
c. Clean Humidifier per instructions.
d. Ensure water in Base is adequate to im-
merse the Water Sensor.
e. Set output to High and wait for 
10 – 15 minutes.
f. See Warranty

PROBLEM: 

Peculiar Odor

  

POSSIBLE CAUSES

a. If new unit 
b. Dirty Water Tank or old water in tank
c. Minerals in well water or hard water

POSSIBLE SOLUTIONS 

a. Rinse Water Tank and Base and let air dry 
b. Empty old water and clean Water Tank per 
instructions.
c.  Use filtered, distilled, cold boiled or bottled 
water

PROBLEM :

White Dust on unit or nearby 

furniture

POSSIBLE CAUSE  

Hard water used  

POSSIBLE SOLUTION

Use filtered, distilled, cold boiled or bottled 
water

PROBLEM: 

Condensation forms 

around humidifier or windows 

POSSIBLE CAUSES

a. Mist output is set too high  
for room size 
b. Direction of mist nozzle

POSSIBLE SOLUTIONS

 

a. Decrease mist output 
b. Change direction of mist nozzle

PROBLEM: 

Water is leaking 

POSSIBLE CAUSES

a. Tank cap not properly attached
b. Water tank not properly attached
c. Unit is not on level surface

POSSIBLE SOLUTIONS

a. Follow item #4 on “filling the water tank”
b. Follow item #6 on “filling the water tank”
c. Place on level surface

7

Summary of Contents for MH-401

Page 1: ...ULTRASONIC DIGITAL HUMIDIFIER Instruction Manual and Warranty Information IM0002A READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...tents Safety Instructions 1 Unpacking Specifications 2 Parts Contents 3 Filling The Water Tank 4 Operating Instructions 5 Weekly Cleaning Care Storage 6 Troubleshooting 7 Other Great Products 8 Warranty 9 ...

Page 3: ...ided with the unit NEVER use the appliance after a malfunction after it has been dropped or damaged in any other way Only operate when fully assembled Keep out of reach of children Close supervision is necessary when this appliance is used by or near children elderly or disabled persons NEVER drop or insert any object into any opening DO NOT block any air outlets or intakes NEVER cover the applian...

Page 4: ...hile working silently to erase the discomforts of dry air Unpacking Specifications Do not take unit out of the box by pulling the water tank Remove the plastic bag from the humidifier Remove filter from box and remove bag Carefully remove the humidifier from the box by pulling from the base of the unit Product Model Power Consumption Rating Voltage Tank Capacity Dimensions Weight MH 505 32W AC110 ...

Page 5: ...e 3 Water Tank 4 Base 5 Control Panel 6 Air Outlet 7 Water Sensor 8 Water Reservoir 9 Ultrasonic Nebulizer 10 Cleaning Brush 11 Ceramic Water Filter 12 Tank Cap 13 Bottom Tank Handle 3 Ultrasonic Digital Humidifier Parts Contents 1 1 3 4 4 5 2 2 13 ...

Page 6: ...he unit and void the warranty Replace the Tank Cap by firmly turning clockwise until tight Turn the Water Tank upright and check the Tank Cap for leaks If any water drips remove the Tank Cap and retighten Do not place Water Tank on the Humidifier Base if the cap is leaking Grab the Water Tank with both hands and replace on the Humidi fier Base make sure to follow the shape of the Water Tank and th...

Page 7: ...nce The unit will remain working but without the display Press any button to wake up the display for one minute Press the LED Dim button once more to turn the display ON LOW Water When the tank is out of water the Waterless indicator will appear in the display and the automatic safety shut off will turn the Ultrasonic Nebulizer OFF You may hear the fan for a few seconds this is normal Timer To use...

Page 8: ... Cleaning If mineral deposits White Dust are evident around the Ultrasonic Nebulizer and Water Sensor clean these surfaces with a soft cloth and a small amount of undiluted white vinegar If necessary mix a solution of 50 white vinegar and 50 water and fill the Base with enough solution to cover the Ultrasonic Nebulizer a Allow it to soak for an hour and thenuse the provided brush to gently loosen ...

Page 9: ... Odor POSSIBLE CAUSES a If new unit b Dirty Water Tank or old water in tank c Minerals in well water or hard water POSSIBLE SOLUTIONS a Rinse Water Tank and Base and let air dry b Empty old water and clean Water Tank per instructions c Use filtered distilled cold boiled or bottled water PROBLEM White Dust on unit or nearby furniture POSSIBLE CAUSE Hard water used POSSIBLE SOLUTION Use filtered dis...

Page 10: ...These Other Great Products For Your Life Available at www qvc com www forlifeproducts com PRODUCTS Inc Font Bank Gothic for 8 Clean Restore Protect For All Hard Floors Wood Cabinets Furniture Coco Doormats ...

Page 11: ...iramar FL 33027 USA Please fill out the warranty card and mail back to the above address Or register your warranty online today Simply go to http www greatinnovations tv warranty php NAME ADDRESS CITY STATE ZIP TELEPHONE E MAIL DATE OF PURCHASE PLACE OF PURCHASE THIS UNIT COMES WITH A ONE YEAR WARRANTY SUBJECT TO THE FOLLOWING CONDITIONS In the first year all repairs will be performed free of char...

Page 12: ......

Reviews: