SAFETY INSTRUCTIONS

• 

Prior to using the appliance, read through the instructions for complete use  

 

 

and keep in a safe place for later reference.

• 

WARNING – DO NOT use outdoors. Only use as intended and described in  

 

 

this manual.

• 

DO NOT expose or immerse the Base in water or other liquids.

• 

Before using the appliance, extend the cord and inspect for any signs of  

 

 

damage. 

DO NOT use if cord has been damaged.

• 

Keep cord away from heated surfaces and out of the way, where it cannot  

 

 

be stepped on or tripped over.

• 

This appliance has a polarized plug (one blade is wider than the other) as a  

 

 

safety feature. If the plug does not fit fully into the outlet, reverse the plug. If  

 

 

it still doesn’t fit, contact a qualified electrician. 

DO NOT attempt to defeat this    

 

safety feature.

• 

Always place humidifier on an elevated firm, flat, level surface; where it’s not  

 

 

easily knocked over. e.g. on a table, chest, cabinet, etc.

• 

DO NOT place the appliance next to a heating vent, under direct sunlight, 

 

high temperature areas, near computers or sensitive electronic equipment.

• 

DO NOT place the appliance directly on wood furniture or other surfaces  

 

 

which could get damaged by water. e.g. waterproof surface or mat.

• 

NEVER use in an environment where explosive gases are present.

• 

DO NOT use any attachments not provided with the unit.

• 

NEVER use the appliance after a malfunction, after it has been dropped or  

 

 

damaged in any other way.

• 

Only operate when fully assembled.

• 

Keep out of reach of children. Close supervision is necessary when this 

 

appliance is used by or near children, elderly or disabled persons.

• 

NEVER drop or insert any object into any opening.

• 

DO NOT block any air outlets or intakes.

• 

NEVER cover the appliance when it’s in operation.

• 

To unplug turn controls to the “OFF” position, then remove the plug from the outlet.  

 

Ensure your hands are dry.

• 

ALWAYS unplug and empty the water tank when not in use for a long period of time.

• 

ALWAYS unplug before removing, filling or emptying the water tank.

• 

DO NOT wash, adjust or move without first unplugging the unit.

• 

DO NOT move appliance with water inside the tank.  In this case remove the water  

 

tank prior to moving.

• 

DO NOT touch the water or any other part in the base during operation.

• 

NEVER operate without water in the tank.

• 

DO NOT use hot water in the tank.

• 

ONLY use water in the tank, never add any additive such as essential oils,  

 

eucalyptus, water conditioners, etc… to the water.

• 

Please hold the water tank by the top handle when carrying full tank of water.

• 

DO NOT attempt to repair or adjust the unit. Servicing must be performed by 

 

professional or qualified personnel.

• 

Discontinue use if unit makes loud noises or has a strange smell.

• 

Perform regular maintenance of the Ultrasonic Nebulizer.

• 

DO NOT direct the mist against a wall or other home appliance.

1

Summary of Contents for clean mist MH-408

Page 1: ...IM0036A READ AND SAVE THESE INSTRUCTIONS CLEAN MIST ULTRASONIC HUMIDIFIER Instruction Manual and Warranty Information...

Page 2: ...ents Safety Instructions 1 Unpacking Specifications 2 Parts Contents 3 Filling The Water Tank 4 Operating Instructions 5 Weekly Cleaning Care Storage 6 Troubleshooting 7 Other Great Products 8 Warrant...

Page 3: ...the unit NEVER use the appliance after a malfunction after it has been dropped or damaged in any other way Only operate when fully assembled Keep out of reach of children Close supervision is necessar...

Page 4: ...tantaneously while working silently to erase the discomforts of dry air Unpacking Specifications Product Model Power Consumption Rating Voltage Tank Capacity Dimensions Weight MH 408 30W 120V 4L 1 1 G...

Page 5: ...ndow 5 Base 6 Humidity Water Sensor 7 Power Mist Control Knob 8 Air Outlet 9 Cleaning Brush 10 Water Reservoir 11 Ceramic Filter 12 Tank Cap 13 Ultrasonic Nebulizer 14 Water Sensor 15 Bottom Tank Hand...

Page 6: ...above so that the tank sits level and flush to the base Ensure the tank is firmly seated Attach Rotating Mist Nozzle to the top of the humidifier tank Use both hands and grab the handle on top of the...

Page 7: ...finger from the nozzle feature See Photo when the Mist Nozzle is in place ON OFF Plug into a standard 120V AC electrical outlet Turn the Mist Control Knob clockwise until you hear a click and the Hum...

Page 8: ...sharp object White Dust Cleaning If mineral deposits White Dust are evident around the Ultrasonic Nebulizer and Water Sensor clean these surfaces with a soft cloth and a small amount of undiluted whi...

Page 9: ...dor POSSIBLE CAUSES a If new unit b Dirty Water Tank or old water in tank c Minerals in well water or hard water POSSIBLE SOLUTIONS a Rinse Water Tank and Base and let air dry b Empty old water and cl...

Page 10: ...8 Try These Other Great Products For Your Life Available at www qvc com www forlifeproducts com Ultrasonic Humidifiers Air Purifiers...

Page 11: ...iramar FL 33027 USA Please fill out the warranty card and mail back to the above address Or register your warranty online today Simply go to http www greatinnovations tv warranty php NAME ADDRESS CITY...

Page 12: ...Air Innovations 2013 Great Innovations LLC All Rights Reserved US International Patents Pending Available In Black Platinum...

Reviews: