background image

1

SAFETY INSTRUCTIONS

•   This appliance has a polarized plug (one blade is wider than the other) as a safety  

 

feature. If the plug does not fit fully into the outlet, reverse the plug. If it still doesn’t  

 

fit, contact a qualified electrician.  DO NOT attempt to defeat this safety feature.

•  Before using the humidifier, extend the cord and inspect for any signs of damage; 

 

DO  NOT use if the cord has been damaged.

•  Keep cord away from heated surfaces and out of the way, where it cannot be   

 

stepped on or tripped over.

•  NEVER use in an environment where explosive gases are present.

•  Place humidifier on a stable level surface where it’s not likely to tip over; 

 

DO NOT place on carpet, next to heating vents, under direct sunlight, in high 

 

temperature areas, or near computers and electronic equipment.

•  DO NOT place the the humidifier directly on wood furniture or other surfaces which  

 

could get damaged by water.

•  DO NOT direct the mist against a wall or home appliances.

•  NEVER operate without water in the Tank; DO NOT use anything other than room  

 

temperature tap or distilled water.

•  DO NOT touch the water in the Base during operation.

•  DO NOT expose or immerse the Base in water when cleaning.

•  DO NOT pour water into the base through the Air Outlet during cleaning and filling.

•  NEVER block the Air Outlet or intake or cover the unit when it’s in operation

•  DO NOT use any attachments not provided with the unit.

•  Discontinue use if humidifier makes loud noises or has a strange smell.

•  DO NOT attempt to repair or adjust the unit; servicing must be performed by 

 

professional or qualified personnel.

•  Potential risk of electric shock due to overfilling or cleaning the humidifier without  

 

disconnecting the power supply cord.

•  Only operate when fully assembled; only use as intended and described in this manual.

•  Keep out of reach of small children.

•  Always insert plug securely into the power source.

•  Unplug the unit and empty the Water Tank and Base before carrying/moving.

•  Only unplug when the humidifier is turned off; ensure hands are dry.

•  Always turn off the unit before removing, emptying or filling the Water Tank.

•  Perform regular maintenance of the Ultrasonic Nebulizer; NEVER scrape Nebulizer with  

 

a hard or sharp object.

•  Dry the unit completely before storage; store in a cool, dry place.

•  Do not drop, hit or otherwise subject this product to excessive shock.

READ AND SAVE THESE INSTRUCTIONS: Failure to follow

all the instructions may result in electrical shock.

WARNING

CAUTION

Summary of Contents for CLEAN MIST AI-101

Page 1: ...READ AND SAVE THESE INSTRUCTIONS CLEAN MIST ULTRASONIC HUMIDIFIER Instruction Manual and Warranty Information...

Page 2: ...on against harmful interference in a residential installation The product generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may ca...

Page 3: ...ose or immerse the Base in water when cleaning DO NOT pour water into the base through the Air Outlet during cleaning and filling NEVER block the Air Outlet or intake or cover the unit when it s in op...

Page 4: ...home or office This Humidifier uses Ultrasonic Top Fill Technology to create humidity instantaneously while working silently to erase the discomforts of dry air Specifications Unpacking Follow direct...

Page 5: ...voir Base 4 SMART Control Panel 5 Water Tank Cover 6 Rotating Mist Nozzle 7 Water Sensor 8 Mist Outlet 9 Air Inlet 10 Ultrasonic Nebulizer 11 Water Sensor Float Top View Water Tank Water Reservoir Bas...

Page 6: ...illing The Water Tank About White Dust Use of high mineral content water may cause a white mineral residue to accumulate on surfaces in the room near the humidifier The mineral residue is commonly cal...

Page 7: ...n 2hr 4hr and 6hr increments Press the button to choose the desired time HUMIDISTAT This unit is factory set to 60 relative humidity When the unit is turned on the current ambient humidity of the room...

Page 8: ...necessary a mild cleaning solution may be used The Water Filter simply snaps onto the base of the Tank To clean remove the filter rinse with water and replace To Clean the Base Empty the water from th...

Page 9: ...is forming on nearby furniture Hard tap water may deposit a certain amount of dust To reduce white dust we recommend filtered or distilled water Water is leaking Humidifier is not on a level surface P...

Page 10: ...8 Try These Other Great Products For Your Life Available at www ForLifeProducts com www Air Innovations com www Pursfection com www RejuvenateProducts com...

Page 11: ...rd and mail back to the above address Or register your warranty online today Simply go to www Air Innovations com NAME ADDRESS CITY STATE ZIP TELEPHONE E MAIL DATE OF PURCHASE PLACE OF PURCHASE THIS U...

Page 12: ...Air Innovations 2020 Great Innovations LLC All Rights Reserved US International Patents Pending Printed in China...

Reviews: