REVERSE OSMOSIS 

AIR GAP

Model:

Old Part Number: 

500 Jefferson Street, Placentia, California 92870 USA • 949-955-3928 • Email: [email protected] 

Copyright  AIR GAP INTERNATIONAL 

Placentia, California

AG110-002

GAP-A-RO, KIT S-B

Doc.#400-0807-001

5. Connect 3/8" OD poly tubing from
your RO unit to AG110-002 inlet port
and 3/8" OD poly tubing from the
AG110-002 outlet port to the drain
pipe. Use provided clamps and
screws to secure tubing. (See FIG
1-5)

4. The AG110-002 must be installed with the "C/L" line
above the sink's rim, sump, floor drain, floor grate, or
standpipe where the discharge tubing is terminated. The
AG110-002must be installed vertically. Secure
AG110-002 with provided mounting screws (See Fig 1-4).

"C/L"

0.857"-0.900"

Critical Level (C/L) marking 

Mounting Screws

Fig 1-4

Fig 1-5

3/8” O.D.

Poly tubing

Clamp

1/4” O.D.

Poly tubing