background image

- INSTRUCTIONS -

The LS-NVP is a vandal proof sub station designed for use with the systems listed above.  The LS-NVP-
W is the weather resistant model.  Both are constructed of 11 gauge carbon steel with a white powder-
coated finish.  The LS-NVP(-W) can be flush or surface mounted with the SBX-NVP.  Each unit includes
tamper proof screws and tool for installation.

LS-NVP (-W)

Vandal Proof Sub Station for LAF-C, LEF, LEM, AP-M, MP-S Systems

SBX-NVP

Surface Mount Box for LS-NVP

Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA  98005
(425) 455-0510
FAX (425) 455-0071

TOLL FREE TECHNICAL SUPPORT:

(800) 692-0200

TOLL FREE FAX LINE:

(800) 832-3765

E-MAIL: [email protected]

LS-NVP Instr

0698bkjd

SPECIFICATIONS:

Power Source:

Supplied by master station

Speaker:

20 ohms, 3" diameter, water proof and puncture resistant, 2.5 oz. ceramic magnet

Call Button:

Single pole, single throw (SPST), normally open (N/O)

Faceplate:

11 gauge carbon steel with powder-coated white baked epoxy finish

Communication:

Hands free at sub.  Master is push-to-talk,release-to-listen

Mounting Hardware:

Tamper proof screws

Terminations:

Color-coded prewired pigtails

Wiring:

RED to # terminal, BLK to "E" (Common) terminal, GRN to "-" terminal
Shielded cable is recommended.
Use Aiphone #822202 or #821802 for homerun wiring, #822206 for up to 4 stations
on each run, or #822210 for up to 8 stations on each run.

Wiring Distance:

650' with 22AWG; 1,600' with 18AWG.

Dimensions (H x W x D):

LS-NVP alone:  7-1/2" x 5-1/2" x 2".  With SBX-NVP:  8-5/8" x 6-5/8" x 2-1/4"

+

-

WIRING DIAGRAM:

1
2
~

10

E

+

-

Red

Blk*

Grn

Red

Blk*

Grn

LAF-C or LEF

Master

LS-NVP

LS-NVP

PS-12C

Switch on PC board:

Leave in the LOWER
position (set from factory),
for use with LEM, LAF-C and
LEF systems

* In  single master system, 2
conductors homerun can be
used with the BLK and GRN
wires tied together and "E"
and "-" jumpered at the
master.

WIRING DIAGRAM:

1

E

~

10

E

AP-M or MP-S

Master

Switch on PC board:

Move to the UPPER position
for use with AP-M or MP-S
systems.

Tie Blk and Grn wires
together for all installations
with the MP-S and AP-M
systems.

Red

Blk

Grn

LS-NVP

Special
Order
Products

Red

Blk

Grn

LS-NVP

Reviews: