- INSTRUCTIONS -

The LA-20AS and LA-40AS add-on selectors are designed to function with LAF-C Console Masters, Type "E" or
later. Multiple add-on selectors can be  added to a master station along with a variety of sub stations to create a
communication system tailored to a user's needs. All standard LAF and LEF system accessories can be used in
conjunction with the add-on selectors.

LA-

n

AS

Add-on selectors for the LAF-C/E Console masters.

LA-20AS, 20-call

LA-40AS, 40-call

Special

Order

Products

Pg. 1

NAMES & FUNCTIONS:

1.  OFF button
2.  Selector button
3.  OFF LED
4.  Directory card
5.  Station selector LED

L-nAS TERMINAL DEFINITIONS:

+

Positive 12V DC

-

Negative

1~40

Station number

E

Common communication

Individual Components for System:

LAF-

nC     

Console type master (20, 40 call capactiy)

LAF-

nCA

Console type master w/handset (20, 40 call capactiy)

LA-20AS 20-call Add-on Selector
LA-40AS 40-call Add-on Selector
PS-12C

12V DC, 1A Power Supply

BG-10C

All Call, Chime and music adaptor. (1 required per 10 stations)

PS-12F

12V DC, 2.5A Power Supply (1 Required per BG-10C)

LS-NVP

Vandal proof sub station (flush mount)

LS-NVP-W

Weather resistant vandal proof sub station (flush mount)

SBX-NVP Surface mount box for LS-NVP and LS-NVP-W
LE-series Any model sub station with  LE- prefix

1

2

5

4

3

SPECIFICATIONS:

Power Source:

12V DC at master.  Use PS-12C, or PS-12F when BG-10C(s) are included (1 PS-12F per BG-10C)

Communication Output: 800mW at 20 ohms (receive); 500mW at 20 ohms (transmit)
Communication:

Push-to-talk, release-to-listen (TALK button), or VOX handset at master. Hands free at sub station.

Calling:

Master to sub or other master:  By voice (TALK) or tone (TALK & ALL CALL simultaneously)
Sub to master:  Call button on sub activates tone and LED at master, remaining lit for approximately
20 seconds.

Wiring:

2 conductors homerun to sub station (1-Master system only), 3-conductor, or loop multi-conductor
with 2 1 individual wire per sub station on wire run.

Shielded cable is recommended.

Use Aiphone #822202, 2 cond. 22AWG; #821802, 2 cond. 18AWG or #822203, 3 cond. 22AWG;
#822206, 6 cond. 22AWG. LA-nAS to ea. BG-10C:  Aiphone #822220, 20 cond. 22AWG.

Wiring Distance:

650' with 22AWG; 1,600' with 18AWG.

Dimensions:

LA-20AS:  10-1/4" x 7" x 5-1/2".

 (H x W x D)

LA-40AS:  10-1/4" x 12-7/8" x 5-1/2".

  