JM-4MED

HANDS-FREE COLOR VIDEO INTERCOM MASTER STATION

JMW-BA

LONG DISTANCE ADAPTOR

JM-8Z

DISTRIBUTION ADAPTOR

INSTALLATION MANUAL

FK1874  B   P0113OZ

JM-4MED

JMW-BA

JM-8Z

Summary of Contents for JM-4MED

Page 1: ... for future reference Also read the installation manuals for the other devices included in your system Please note that the illustrations in this manual may differ from the actual product JM 4MED HANDS FREE COLOR VIDEO INTERCOM MASTER STATION JMW BA LONG DISTANCE ADAPTOR JM 8Z DISTRIBUTION ADAPTOR INSTALLATION MANUAL FK1874 B P0113OZ JM 4MED JMW BA JM 8Z ...

Page 2: ...g the option connectors 12 MOUNTING 13 Mounting locations 13 Mounting procedure 14 SETTINGS AFTER INSTALLATION 16 Setting list 16 INSTALL menu 16 Setting for inputs and outputs 17 Door release settings SET DOOR RELEASE 18 Initializing station INITIALIZE 19 Identifying software version SOFTWARE VERSION 19 TECHNICAL DATA AND PRECAUTIONS 19 WARRANTY Back cover Term definition This manual uses residen...

Page 3: ... sulfide hot spring Places subject to moisture and humidity extremes such as bathrooms cellars greenhouses etc Places where the temperature is quite low such as inside a refrigerated area or in front of an air conditioner Places subject to steam or smoke near heating or cooking surfaces Where noise generating devices such as dimmer switches or inverter electrical appliances are closeby 10 Be sure ...

Page 4: ... 1 2 3 4 5 6 7 8 Pair2 Pair1 T568A Pair4 Pair2 Pair3 Pair1 T568B Notes on CAT5e cables for residential stations Do not bend the cables to an extent where the radius is less than 25 mm 1 Communication failure could result Do not remove the CAT5e cable jacket more than necessary This unit is not a computer peripheral Do not connect it to a LAN network CAT5e cable 25mm 1 or more Less than 25mm 1 CAT5...

Page 5: ...r master station 50 m 165 75 m 245 100 m 330 100 m 330 D Master station power supply 5 m 16 5 m 16 10 m 33 10 m 33 E Long distance adaptor power supply 50 m 165 75 m 245 100 m 330 100 m 330 F Master station external display 3 m 10 G Long distance adaptor CCTV camera 15 m 50 H Master station multiple door release adaptor 50 m 165 75 m 245 100 m 330 100 m 330 I Master station optional call extension...

Page 6: ...er station Long distance adaptor Master and sub master stations 1 4 Master and sub master stations with long distance adaptors 1 3 4 Sub master stations only 6 2 Supplying power to sub master stations via wiring with the master station PS24 PS24 PS24 The following chart indicates how many units can be powered by a single power supply Combination of units Master station Sub master station Long dist...

Page 7: ...G Ø0 8 mm 20 AWG Ø1 0 mm 18 AWG Ø1 2 mm 16 AWG A 5 m 16 5 m 16 10 m 33 10 m 33 B 300 m 980 C 150 m 490 200 m 650 300 m 980 300 m 980 When powering up to one master station and four sub master stations D 150 m 490 200 m 650 300 m 980 300 m 980 When powering up to six sub master stations E 30 m 98 Up to 50 m 165 when powering master and one sub master stations F 30 m 98 When powering up to three sub...

Page 8: ...tor cable Master station ID 1 JM 4MED Door station 1 JK DA JK DV JK DVF JM DVF L Door station 2 Door station 3 Optional call extension speaker IER 2 P 12 P 12 12 pin option connector 4 pin option connector Electric door strike EL 12S Electric door strike EL 12S Sub master station 1 ID 2 JM 4HD Sub master station 2 ID 3 JM 4HD Sub master station 3 ID 4 JM 4HD Sub master station 4 ID 5 JM 4HD Sub ma...

Page 9: ...ted For connecting other manufacturers products refer to the instruction manuals for those products The positions of the terminals on the above illustrations differ from the actual product This is to simplify the diagram This unit is not a computer peripheral Do not connect it to a LAN network CAT5e non shielded Ø1 0mm 18AWG 2 conductor cable Distribution adaptor JM 8Z Sub master station 3 ID 4 JM...

Page 10: ...tion in place of a video door station or Video door station JK DA JK DV JK DVF JM DVF L NOTES An optional audio door station installed with a CCTV camera provides door call in audio monitoring and communication with visitors Video input 1 Vp p 75 Ω When a PAL camera is used the display range gets narrower than the imaging range Turn on the units in the following order the CCTV camera the long dist...

Page 11: ... 2A1 b1 L1 b2 C1 b3 L E L1 L3 C3 L3 L2 C2 L2 P 2 P 2 Master station JM 4MED Door station 1 JK DA etc Electric door strike 1 EL 12S Electric door strike 2 EL 12S Electric door strike 3 EL 12S Electric door strike 4 EL 12S 4 pin option connector 4 pin option connector identifies active door b1 is brown lead active with door 1 b2 is red lead active with door 2 b3 is orange lead active with door 3 b4 ...

Page 12: ...ad DC 5 V 100 mA 5 Video out Outputs video signals to an external monitor DVR etc NTSC PAL 1 Vp p 75 Ω Wiring distance 3 m 10 feet NOTES A video signal is output while receiving a call from communicating with or monitoring a door station A playing image will not be output When a video signal is output this station may produce a noise depending on the installation environment When the image on the ...

Page 13: ...G Mounting locations Install this station in a place where the screen is not exposed to direct sunlight Allow at least 15 cm 6 above center of the mounting bracket for installation of the station 15 cm 6 or more ...

Page 14: ...nect or disconnect wires Insert the wire into one of the coupling terminals To ensure that the wire will not bend press the release button while inserting into terminal Opening closing the terminal cover To open Slide the cover to the right until it clicks and then open To close Close the cover and then slide it to the left until it clicks Make sure the cover is locked Release button 8mm 3 8 Termi...

Page 15: ...it directly on the wall using wood mounting screws JM 8Z Mount the unit directly on the wall using wood mounting screws Cable inlet plate Mounting bracket pre attached by factory The unit The unit The unit Wood mounting screw 4 included Wood mounting screw Ø4 1 slotted head Ø8 2 or less 2 not included Wood mounting screw Ø4 1 slotted head Ø8 2 or less 2 not included Wires CAT5e cable 83 5mm 3 5 16...

Page 16: ...ivate the connected external devices NOTES These settings should be made by the installer before the system is used It is recommended to set the display language for the screen to the language needed Default language English Refer to the Operation manual for setting the language Setting list Item Sub item Setting range Default INSTALL SECURITY SENSOR INPUTS Usage of the inputs 1 3 DISABLE UTILITY ...

Page 17: ... usage of the inputs 2 Touch this to change the input detection method between N O Normally Open and N C Normally Closed Usage list Usage Description DISABLE Select this when no connection is made to the inputs UTILITY Select this when a sensor etc is connected to the inputs for triggering the alarm SECURITY Select this when a sensor is connected to the inputs for using the security function of th...

Page 18: ... Procedure Touch the preferred action so that it is highlighted Up to four actions can be selected When finished adjusting the settings touch 3 ENTER Door release settings SET DOOR RELEASE Adjust the settings for controlling the door release devices connected to the L1 and L2 terminals From th 1 e INSTALL menu window touch SET DOOR RELEASE The SET DOOR RELEASE window is displayed Touch 2 LOCK1 to ...

Page 19: ...use an abrasive cleaner or cloth Initializing station INITIALIZE By initializing this station all settings return to default Recorded images on the SD or SDHC card are not be erased From th 1 e INSTALL menu window touch INITIALIZE A notice message is displayed Touch 2 YES to continue initializing To cancel initializing touch NO When INITIALIZATION COMPLETE is displayed initializing is complete Ide...

Page 20: ...s warranty Aiphone will not be responsible for any costs incurred involving on site service calls Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products during use or for any consequent inconvenience or losses that may result The object area of is the EU FCC This device complies with Part 15 of the FCC Rules Operation is subject to the...