5-52
Chapter 5: SYSTEM SETTINGS BY SOFTWARE
5.8. Paging Zone Settings
Step 1.
Click "Paging" to display the following setting screen.
Step 2.
Enter the paging number digit.
Enter the number 1, 2 or 3 in the input box for [Paging No. digit].
Zones are automatically indicated depending on which number is set. (For example, entering "1"
displays zones 1 through 9 for editing, entering "2" displays zones 01 though 99 for editing, etc.) The
maximum number of zones is 160.
Step 3.
Enter the paging port number to be used.
Enter the start paging port number to be used in the system. The valid range is from 1 to 65535. The
AN-8000 system uses (the number of Exchanges) x 4 and (the number of Multi interface units) x 2
consecutive ports starting with the start port.
Note
Take care not to duplicate the number with the UDP port number set on
15000 that is internally used.
Step 4.
Enter a zone name.
Double-clicking the cell (paging 1 – ) located under the zone number allows the zone name to be
edited. The zone name can be up to eight characters long.
Step 5.
Select stations and external PA paging outputs included in each zone.
Click the desired cell to checkmark it.
Summary of Contents for AN-8000EX