![AiP ABL-005IR Manual Download Page 45](http://html.mh-extra.com/html/aip/abl-005ir/abl-005ir_manual_2872213045.webp)
SWIR Line Camera Series User’s Manual
(OM150000013H-EN)
-
45
-
4-15
Encoder
Encoder can be connected to Line0, Line1 and it counts 2
phases signal to generate triggers by the specified ratio of
the duration.
NOTE
ABL-010IR-CL is not supported.
Following is a diagram of an Encoder block.
4-15-1
Trigger Selector
Select the signal of each phase in phase decoder.
Phase A
command
param1
CL
enc-phasea-source
255
:
Off
32
:
Line0
34
:
Line1
GV
EncoderSourceA
Off
Line0
Line1
Phase B
command
param1
CL
enc-phaseb-source
255
:
Off
32
:
Line0
34
:
Line1
GV
EncoderSourceB
Off
Line0
Line1
NOTE
Be sure to set phase A and B with one each between Line0
and Line1. In case only one of phase A or B is configured
or both phases are set to the same Line, the encoder does
not work correctly.
4-15-2
Counter
Up/Down signal which is output from a PhaseDecoder is
counted, and counting is performed in 64bit including the
symbols. The counted value of 64bit is acquired by means
of following command
command
CL
enc-value
GV
EncoderValue
NOTE
In case Encoder Value is programmed, count is started
when the next encoder circuit is activated or executing
Encoder Reset.
Encoder Control
Encoder0
Phase
Decoder
Divider
OutputMode
Sampling CLK
(6.25MHz)
PhaseA PhaseB
UP
DOWN
Trigger
Selector
Value
ValueAtReset
PhaseATriggerSource
PhaseBTriggerSource
Status
Status
Counter
OutputMode
Mode
Divider
Line0
Line1
Trigger Signal Grid
Count
value
TimeOut
Trigger Output
Trigger
Selector
Reset
FF
MUX
ResetTriggerSource
ResetActivation
A
B
Forward
Forward
Reverse
The resolution of the encoder