![AiP ABL-005IR Manual Download Page 19](http://html.mh-extra.com/html/aip/abl-005ir/abl-005ir_manual_2872213019.webp)
SWIR Line Camera Series User’s Manual
(OM150000013H-EN)
-
19
-
3-2
CameraLink Configuration
3-2-1
Communication Settings
CameraLink camera is configured by RS-232C protocol
via serial port assigned to a CameraLink frame grabber.
It is done by asynchronous serial communication by start-
stop transmission and its transfer control specification is
indicated below. Echoback is activated against the
command input, and it does not matter to send the
commands start whether with uppercase or lowercase.
Baud Rate
115200/57600/38400/19200/9600 [bps]
Data Bit
8Bit
Parity
N/A
Stop Bit
1Bit
Flow Control
N/A
※
Underlined value means default value(same after here)
3-2-2
Camera Control Software
Camera parameter setting is done by sending commands
via serial interface, and it requires the installation of
software named
Tera Term
for serial communication.
3-2-3
Serial Port Configuration
After starting Tera Term, go up to Setup > Serial Port.
You'll see a window pop up with a lot of familiar looking
serial port settings. Adjust as shown below and click "OK".
・
Port
:
Comport number assigned to CameraLink
Interface
・
Baud Rate
:
115200bps(Camera Default)
・
Data Bit
:
8bit(Fixed)
・
Parity
:
N/A(Fixed)
・
Stop Bit
:
1bit(Fixed)
・
Flow Control
:
N/A(Fixed)
3-2-4
Terminal Setup
Go to
Setup
menu and select
Terminal
on the menu, and
you will see the window as shown below, then set Receive
to CR+LF, Transmit to CR.
3-2-5
Connection Confirmation
When Tera Term setting is completed, hit
Enter
key. If the
Tera Term terminal window shows OK>, now it is all set to
communicate with the camera.