DC TO AC POWER INVERTER

 

 

PWRB1250W

 

 
 
 

INSTRUCTION MANUAL

 

 
 
 
 
 
 
 

 

 

 

Summary of Contents for PWRB1250W

Page 1: ...DC TO AC POWER INVERTER PWRB1250W INSTRUCTION MANUAL...

Page 2: ...Red battery terminal Connect Black battery cable to Black battery terminal Alligator clamp cables may be used but only to connect to the battery Do not use clamps on inverter terminals Alligator clam...

Page 3: ...dren Size the inverter properly Size the inverter for the surge rating of your equipment The inverter s continuous rating should be MORE than the surge rating of your equipment Example Power tool runs...

Page 4: ...ARRANTY OF YOUR INVERTER SO BE CAREFUL TO CONNECT YOUR INPUT WIRES PROPEPLY If you choose to operate a battery charger to replenish your battery s voltage be sure to check with charger manufacture bef...

Page 5: ...f the unit makes it an electrical shock hazard if operated with wet hands Allow at least 12 inches of clearance around the Inverter for air flow Ensure the ventilation openings on the rear and bottom...

Page 6: ...oads for extended period the inverter will shut down to prevent damage from excess heat Simply reduce your load and allow the Inverter to cool down Low battery shutdown Recharge your battery and resum...

Page 7: ...Alarm DC 10 5 _ 0 5 V Battery Low Shutdown DC 9 5 _ 0 5 V Operating Temperature Automatic Recovery Shutdown 30 130 F Internal DC Input Fuse Must be fitted use 25A 3 max Fan Thermal Remote Switch Port...

Page 8: ...tomer Except as provided above AIMS makes no warranty of any kind express or implied including without limitation the implied warranties of merchantability and fitness for a particular purpose In no e...