background image

 

LCU-ONE Analog

User Manual

Release 1.02

 

1

Chapter 2 – LCU-ONE and Lambda probe mounting 

LCU-ONE

 controller should be installed in a flat location and far from heat sources; it 

should be mounted steady using the suited bracket. 
The wiring has to be arranged so to avoid it passing near to heat sources.  

LCU-ONE

 is to be powered by the engine master switch.  

BOSCH LSU 4.9 Lambda probe should be installed on the vehicle exhaust pipe using a 
specific adaptor that comes with the kit and should be welded on the same pipe. The 
probe should be sufficiently near to the engine. 
Probe working temperature should not exceed 900°C (1652°F) and it should not be 
exposed to the free flame coming from the exhaust system. 
Probe installation angle should be of at least 10° to avoid liquid condensation stuff to 
come in contact with the probe, polluting it. 

 

Once the probe is installed, pay attention not to let the cable pass near to excessive 
heat sources (the exhaust pipe for example). 
Bosch LSU 4.9 probe auto-calibrates: no calibration is then required by the user. 

Solvents or additives should not be used to clean the probe connector. To protect 
the probe we would suggest to remove it from the vehicle when cleaning the 
vehicle to avoid polluting the probe with detergents. 

It is reminded to never switch the vehicle on with Lambda probe installed and not 
connected to a correctly working 

LCU-ONE

 controller: a probe not heated and exposed 

to exhaust gas would be irremediably damaged. 

N.B. BOSCH LSU 4.9 Lambda probe has been designed to be used with unleaded 

or diesel engine: it can be used with other kind of engines too but its duration 

needs to be tested by the user. 

www.aim-sportline.com

 

3

Summary of Contents for LCU-ONE

Page 1: ...LCU ONE Analog User manual Release 1 02 AiM Infotech...

Page 2: ...guration 4 3 2 LCU ONE Analog custom configuration 7 3 2 1 Preliminary operation 8 3 2 2 Configuring Lambda controller 8 3 2 3 The keyboard 11 3 2 4 Informative panels 11 3 2 5 The analog output graph...

Page 3: ...ut gasoline for example it needs 14 57 parts of air to completely burn a part of gasoline obtaining Lambda value 1 read by the probe LCU ONE controller can detect lambda values in a range of 0 65 to 1...

Page 4: ...of at least 10 to avoid liquid condensation stuff to come in contact with the probe polluting it Once the probe is installed pay attention not to let the cable pass near to excessive heat sources the...

Page 5: ...dard is possible only if calibration curve default points 1 95 0 65 and 4 8 1 6 have not been modified To configure LCU ONE Analog with Race Studio Configuration follow this procedure run the software...

Page 6: ...e probe configuration panel that appears bottom left of channel layer highlighted in the image below Activate the drop down menu pressing the arrow button circled in the image above and select the fue...

Page 7: ...se and only in case its stoichiometric value is known press the button Add custom value and the window here below appears Insert the new value and the test to match Press Add new item to the list butt...

Page 8: ...1 00 07 or later To configure LCU ONE Analog run the software The following window appears This is software main window It is made up of two layers Lambda controller configurator it shows analog outpu...

Page 9: ...download latest release and follow carefully this procedure connect LCU ONE Analog to the PC read logger firmware version written in the case on the left of the central graph press Upgrade Firmware bu...

Page 10: ...in case its Stoichiometric value is known press Add custom value button and the window shown below appears Fill in the window with Multiplier value and related legend Press Add new item to list value...

Page 11: ...ured button placed on the left of the cases indicates the colour of this value on the central graph In the example the value is showed in light blue Once decided which values to show just fill in the...

Page 12: ...r to change the language OK allows the user to save the set parameters Exit allows the user to quit discarding changes 1 03 2 4 Informative panels On top left of the software main window a series of p...

Page 13: ...ndence of the measured Lambda values Graph colours are customizable Pressing Colour options button the window shown below appears Pressing each button a colour panel will appear showing all the availa...

Page 14: ...lease 1 02 3Chapter 4 Online values from Lambda controller This panel shows controller status The user is only allowed to set Lambda AFR and temperature unit of measure for the values shown in this pa...

Page 15: ...nd technical drawings 6 A Part number of LCU ONE Analog Complete kit with cable for MyChron3 XGLog X08LCU04XG Complete kit with cable for MyChron3 Plus Gold Auto Moto X08LCU04PG Lambda Probe Bosch LSU...

Page 16: ...LCU ONE Analog User Manual Release 1 02 www aim sportline com 15...

Reviews: