3.1.6 Booting the device into emergency mode
The ANET1553 device offers an
‘Emergency Boot Button’ on the back panel of the
device:
Figure 3-13 Emergency Boot Button
The emergency system can be used to start up the device whenever the normal system
start up does not work. It can be used to reset the device to factory settings or perform
software updates.
Press the emergency button while powering on the device, e.g. with a paper-clip, in
order to boot the ANET1553 into the emergency mode. The emergency mode boot is
indicated by a red blinking LED. When booting into the emergency mode, the device will
start up with its default factory settings, e.g. user name, password and IP address. You
are able to connect to the ANET1553 device with your web browser now.
3.1.7 How to connect Applications to the ANET1553
The following chapters describe how to connect an ANET1553 with PBA.pro or any
customer specific application using the AIM Application Programming Interface Library
(API-Library).
3.1.7.1 Connect to a ANET1553 with PBA.pro
Open the “Help\About\Settings” tab in PBA.pro and setup the “servers_ppmil” setting to
the alias name or IP address used for your ANET1553
, e.g. “ANET1553-3.local” (see
Figure 3-14 below) and re-start the PBA.pro.