11 - Digital modulation (Option UO1)
Modulation and Sync outputs
38
TGR2050 Series Instruction Manual
Modulation and Sync outputs
The internal modulation signal and the sync signal can both be used as an external
source, through the MOD IN/ OUT and SYNC OUT connections on the rear panel of
the instrument.
NOTE
Modulation must be enabled before the output signal will be available from the rear
panel.
Modulation output (
MOD OUT
)
The digital signal is encoded and filtered before being used as the modulation
source.
ASK, OOK, MSK, or PSK
When selected as the modulation type, the options will be
On
or
Off
. To activate the
modulation output, select the
Mod. Out
parameter window, select
On
and touch
OK
.
Modulating
Bit Pattern
Encoded
Bit Pattern
Filtered
Bit Pattern
Modulating
Waveform
Internal
Modulation
Generator
Encoding
Block
Filter Block
Deviation
Depth
Modulating
Bit Pattern
Encoded
Bit Pattern
Filtered
Bit Pattern
Binary Data
Encoded Data
Filtered Data
Modulating
Waveform
Internal
Modulation
Generator
Encoding
Block
Filter Block
Deviation