background image

20

SPECIFICATIONS & TECHNICAL DRAWINGS (continued)

Copy of marking plates

Summary of Contents for VG890B

Page 1: ...attress Retainer Bed Head VG892H Mattress Retainer Bed Side VG892HA Fixing and Maintenance Instructions This file is available to view and download as a PDF at www aidapt co uk Sight impaired customers can use a free PDF Reader such as adobe com reader to zoom in and increase the text size for improved readability ...

Page 2: ...60601 1 2006 A1 2013 IEC 60601 2 52 2009 A1 2015 IEC 60601 1 2 2014 EN 60601 2 52 2010 A1 2015 EN 60601 1 2 2015 It is also CE marked and is FDA and RoHS compliant The Houghton hospital bed is an electronically actuated acute care bed which is appropriate for adult patient care allowing if required the patient to adjust their own position in the bed Alternatively the bed position can be locked The...

Page 3: ...ton Heavy duty rectangular frame epoxy coating Choice of colour for head and foot board Drop down cot sides optional Lifting pole optional 2 section IV pole optional Packaged ready for transportation with transport brackets included Mattress retainers 6 in all Emergency stop button 4 braked castors Easy cleaning 11 function handset with lock function 4 section metal mattress support Easy assembly ...

Page 4: ...Device Hand control emergency controller Side Rail European side rails at each side of the bed Actuator Independent actuator system under bed deck bed boards UNFOLDED POSITION 1 Bed Board 2 Back Deck 3 Knee Deck 4 Foot Deck 5 Mattress Retainer 6 Motor 7 Bed Frame 8 Castor 9 Emergency Controller 10 Power Cord Suspension Device ...

Page 5: ...or Hi Lo Hand Control with locking function Motor for Knee Rest Emergency Controller Motor for Trendeleburg Link Pin Packing Connector Motor Circuit Power Circuit Controller Circuit Motor Circuit Motor Circuit Motor Circuit FOLDED POSITION fig 1ASSEMBLY BREAKDOWN DIAGRAM ...

Page 6: ...low 3 ASSEMBLY OF BED Recommended 2 person assembly A video of the assembly is available at www aidapt com A Installing the bed frame junction block Take out M10x20 bolt from the 50x30 rectangular tube of bed head frame pull up the bed frame junction block matching the first bolt hole and fasten using M10x20 with ø10 spring washer and ø10 flat washer Do not over tighten the bolt make sure the bed ...

Page 7: ...fig 3 and take out the bed head frame and bed foot frame D Pull out 4 link pins from packing connector see fig 4 E Holding the bed board lift up the packing connector and take it off see fig 5 Pull out the link pins fig 3 fig 4 Lift up the packing connector fig 5 ...

Page 8: ...ion block tighten with screw see fig 6 G Installing bed boards One hand holding up the bed head or foot board the other hand lifting the bed frame insert the installation bolt into the slot see fig 7 H Insert the link pin fig 8 I Two bed boards and bed frame after installation see fig 9 fig 6 fig 7 fig 8 fig 9 ...

Page 9: ...ach the plastic retainer after connecting the wires L Put the mattress retainers onto the bed frame see fig 11 1 Hand control wire 2 Motor wire for height adjustment bed foot 3 Motor wire for height adjustment bed head 4 Motor wire for knee rest 5 Motor wire for back rest 6 Power cord wire fig 10 1 2 4 5 6 3 fig 11 ...

Page 10: ... pole lifting pole The maximum mass for the accessories are below Side rails 12 5kg set safe working load 30kg IV pole 0 6kg pc safe working load 5kg Lifting pole 2 8kg pc safe working load 75kg INSTALLATION AND OPERATION OF SIDE RAILS A video of the assembly is available at www aidapt com A At ideal position of the bed frame insert the side rail base into 50x30 rectangular tube see fig 12 Put on ...

Page 11: ... of a power cut or any emergency situation the bed can be returned to flat position in 30 seconds by pressing the CPR button on the hand control D The bed has collapsible side rails to facilitate transportation cleaning and nursing E Four castors with brake facilitate the bed movement Engaging the brake feature will prevent the bed from moving F The bed operation can be locked by a key attached to...

Page 12: ...nd Reverse Trendelenburg Press and hold the Trendelenburg button to reach your ideal tilting angle Press and hold the Reverse Trendelenburg button to reach your ideal tilting angle Return to flat position Press the Bed Up button to the flat position E CPR Button Returns the bed to a flat position in 30 seconds in case of a power cut or an emergency situation F Operation for emergency controller Pr...

Page 13: ...ord must be hung on the device kept away from the ground and any working components or mechanisms 7 CLEANING AND MAINTENANCE Not suitable for automatic washing systems or jet stream The bed can be washed using neutral soapy water or cleaner After thoroughly cleaned and dried the shaft parts should be lubricated with grease DISINFECTION PROCESS Under normal circumstances the user only needs to clea...

Page 14: ...Check to ensure the normal operation of the motors C Rechargeable Battery It is equipped with OT1 3 12 rechargeable battery with two to four years life span The rechargeable battery is lead acid it should be placed in a cool and dry place when not in use Recharge the battery every month Replace the scrapped battery as per the following instruction Remove the screw form the control box housing and ...

Page 15: ...al components that would cause damage and leakage After product life span all original electrical components shall be recalled The recall should be performed by qualified company The bed should be left in its lowest position when the patient is unattended in order to reduce risk of injury due to falls If a patient for example loses sense of direction due to drugs or clinical conditions he may be s...

Page 16: ...205mm Package size bed folded L960 x W440 x H1230 Bed Deck Size L1956 x W760mm Packaged size bed rails pair L1860 x W205 x H140mm Net weight of bed 88kg Gross weight of side rails pair 14kg It is very important to read the manual and its safety instructions before use of the bed If required the manual can also be downloaded from www aidapt com DANGER TO LIFE On first use or a change in occupant or...

Page 17: ...17 SPECIFICATIONS TECHNICAL DRAWINGS continued ...

Page 18: ...ing Maximum patient weight 200kg Safe working load 235kg including maximum patient weight the mass of mattress IV pole lifting pole and the safe working load of IV pole Lifting pole The degree of protection against harmful ingress of water and particulate matter Type B Equipment Medical bed for adults Marking of replacement mattresses ...

Page 19: ... comes with the symbols icons and safety notes indicating the follwoing meaning Marking of detachable side rails Serial number Supplier Manufacture date AUTHORISED REPRESENTATIVE IN THE EUROPEAN COUNTRY Consult the accompanying documents Copy of marking plates ...

Page 20: ...20 SPECIFICATIONS TECHNICAL DRAWINGS continued Copy of marking plates ...

Page 21: ... cord for damage IMPORTANT INFORMATION The information given in this instruction booklet must not be taken as forming part of or establishing any contractual or other commitment by Aidapt Bathrooms Limited Aidapt Wales Ltd or its agents or its subsidiaries and no warranty or representation concerning the information is given Please exercise common sense and do not take any unnecessary risks when u...

Reviews: