background image

9. 

Raise or lower table top to desired height and tighten thumb wheels by turning clockwise to secure 

(see fig. 15)

. Ensure height is the same on both sides; otherwise, table will not be level and not safe 

for use.

10.  To adjust height loosen thumb wheels anti-clockwise 

(see fig. 16)

 and repeat step 9.

ASSEMBLY INSTRUCTIONS (CONTINUED)

(fig. 15)

(fig. 16)

OPERATION INSTRUCTIONS

• 

To adjust the height and/or angle of the table, first loosen the two short hands screws by turning 
them anticlockwise. Adjust the table to suit and secure by turning hand screws clockwise.

• 

The table is not load bearing and should not be used to support objects over 15kgs (33lbs). 

• 

Do not allow people to lean on the table.

WARNING: The Overbed Table requires a risk assessment before use.
WARNING: The Overbed Table must be checked periodically to ensure it is securely in place, 
retighten as required. 
WARNING: DO NOT overtighten the screws otherwise this will cause damage to table top. 
WARNING. DO NOT EXCEED 15kg weight load.

CLEANING

All of the product components are manufactured from quality materials. However, it is very important 
that you only clean your Over Bed Table using a non-abrasive cleaner or mild detergent with a soft cloth 
avoid using lime scale remover. Abrasive cleaners or abrasive cleaning pads will seriously damage your 
product beyond repair.
If to be disinfected by heat (apart from the wooden table top), one of the following three temperatures 
and duration of exposure can be used:
a. 

a temperature of 90°C for 1 minute 

b. 

a temperature of 85°C for 3 minutes

c. 

a temperature of 80°C for 10 minutes

Summary of Contents for VG832B

Page 1: ...VG832B VG866B Overbed Table Fixing and Maintenance Instructions EN ...

Page 2: ... upstand and the top can also be set to different angles from flat to 45º approximately as required 1 Fixing and Maintenance Instructions BEFORE USE FEATURES Carefully remove all packaging Avoid using any knives or other sharp instruments as this may damage the surface of the product Check the product for any visible damage If you see any damage or suspect a fault do not use your product but conta...

Page 3: ...e purchased the VG832B with castors follow this step otherwise move on to step 3 Locate the pre punched castor holes on the base frame fig 2 align the castor and screw in with spanner J provided see fig 3 Ensure castors are fully tightened 3 Turn the U frame over so that the spigots are facing up Lower the H frame onto the spigots of U frame see fig 4 Ensure the black plastic collars on the H fram...

Page 4: ... the L shape tube onto the underside of the table top observing the following VERY IMPORTANT The riveted end of L shape tube MUST be placed onto the underside of table top see fig 8 The riveted end of L Shape tube MUST be placed between pre drilled holes nearest to the edge of the table approximately 10 cm from table edge see fig 9 and 10 ASSEMBLY INSTRUCTIONS CONTINUED fig 6 fig 7 fig 8 fig 9 fig...

Page 5: ...mage to the table 7 Insert the free ends of L shaped tubes into the H Frame see fig 13 You may require assistance to align them correctly Slowly lower the table top see fig 13 Ensure you lower both sides at the same time to prevent binding 8 Loosely attach two thumbwheels to the small spigots at top of H frame see fig 14 ASSEMBLY INSTRUCTIONS CONTINUED C Bracket MUST be in between the two rivets f...

Page 6: ...ING The Overbed Table requires a risk assessment before use WARNING The Overbed Table must be checked periodically to ensure it is securely in place retighten as required WARNING DO NOT overtighten the screws otherwise this will cause damage to table top WARNING DO NOT EXCEED 15kg weight load CLEANING All of the product components are manufactured from quality materials However it is very importan...

Page 7: ...lacement or refund If your product fails within the guarantee period please contact the retailer from whom you bought it If you have received your product and require technical help please call our help desk on 01744 745 020 A copy of the instructions leaflet can be downloaded from our website IMPORTANT INFORMATION CARE MAINTENANCE AND YOUR OBLIGATION The information given in this instruction book...

Page 8: ...Aidapt Bathrooms Ltd Lancots Lane Sutton Oak St Helens WA9 3EX Telephone 44 0 1744 745 020 Fax 44 0 1744 745 001 Web www aidapt com Email sales aidapt co uk ...