SB405-PV User Manual
Chapter 3.Hardware Settings
3�7�2 LEDs: 30 Bay
SAS PHY Link
Status
(LEDA1 to
LEDA8)
Blue (On)
Link up.
Blue (Blinking)
Activity is detected.
Off
Link down.
Expander Blink
(LED31)
Blue (Blinking)
Expander is alive, 0.0833Hz (12 seconds
per cycle)
Expander Heart
Bit (LED33)
Blue (Blinking)
Expander FW is running
HDD Activity
LEDs
Blue (On)
HDD is present.
Blue (Blinking)
HDD Activity is detected : 8Hz
HDD Locate : 0.5Hz
Off
HDD is not connected or the Power is
off.
HDD Fault/
Status LEDs
Red (On)
Set by any of the following bits:
1. RQST MISSING
2. RQST FAULT
Red (Blinking)
Set by any of the following bits:
1. RQST CONS CHECK
2. RQST IN CRIT ARRAY
3. RQST IN FAILED ARRAY
4. RQST REBUILD/REMAP
5. RQST R/R ABORT
6. RQST INSERT
7. RQST REMOVE
8. PRDFAIL
Off
No control bit is set or set by any of the
following bits:
1. RQST OK
2. RQST RSVD DEVICE
3. RQST HOT SPARE
4. RQST ACTIVE
5. DO NOT REMOVE
6. RQST IDENT
7. DEVICE OFF