![AIC N 100 WH Installation And Maintenance Manual Download Page 52](http://html1.mh-extra.com/html/aic/n-100-wh/n-100-wh_installation-and-maintenance-manual_2870754052.webp)
I-52
Z-038791_EN • Rev A
M
aintenance
Removing and Installing the Fan and Air-
Gas Mixer Assembly
Conditions:
Tools and material:
î
Wrench, hex head, size 5
î
Wrench, flat
î
Torque wrench
Removal Procedure:
1.
Disconnect all connectors and ground wires
from the electrodes, the fan and the gas
valve.
2.
Disconnect the air inlet duct (
1
) from the air-
gas mixer.
3.
Release gas pipe connection (
2
) from the gas
valve (
3
).
4.
Release three screws and washers (
4
) secur-
ing the fan assembly (
5
) to the burner door.
5.
Remove the assembly (
5
) formed by the fan,
the air-gas mixer and gas valve. Retain for
reinstallation.
6.
Remove the fan gasket (
6
) and retain, as re-
quired, for reinstallation.
When removing the gasket, check its
general condition. Discard and re-
place the gasket if it is cracked or
torn.
7.
Remove the electrodes, as required, refer to
“Removing and Installing the Ignition and
Ionisation Electrodes” on page
I-51.
8.
Remove the burner, as required, refer to
“Removing and Installing the Burner” on
9.
Clean the combustion chamber, as required,
refer to
“Checking and Cleaning the Com
OFF
i
Installation Procedure
1.
Install the fan assembly (
5
) with a new gas-
ket (
6
) (if required) on the burner door, using
three retained screws and washers (
4
).
2.
Torque the screws (
4
) at 4 Nm.
3.
Connect gas pipe (
2
) to gas valve (
3
)
4.
Connect the air inlet duct (
1
) to the air-gas
mixer.
5.
Reconnect all connectors to the electrodes,
gas valve and fan.
Follow-on task(s):
1.
Close all panels, refer to
stalling the Access Panels” on page
2.
Restart the boiler, as required, refer to