1

Dry Cooler Type DXP120

30267880

Directions for use

DXP120

Summary of Contents for DXP120 Series

Page 1: ...LU VE Sweden AB Tel 46 454 334 00 S dra Industriv gen 2 4 Fax 46 454 320 295 SE 374 50 Asarum Sweden 1 Dry Cooler Type DXP120 30267880 Directions for use DXP120...

Page 2: ...ect cranking fans and in certain types of machinery control equipment is included Product range Dry Coolers XPS XPM XP DXP X2 D VX2 D X3 D VX3 D VXX3 D We declare that our Dry Coolers and Air Cooled C...

Page 3: ...S dra Industriv gen 2 4 Fax 46 454 320 295 SE 374 50 Asarum Sweden 3 Dry Cooler Type DXP120 General description 4 System of designations 5 Receiving and fitting 6 Installation 7 Preventive maintenance...

Page 4: ...ooler is provided with axial fans and the casing is made of aluminum sheeting as standard Important Do not allow the product to be covered by foreign objects when in operation Unobstructed circulation...

Page 5: ...together with the technical leaflet Location Place the cooler so that air can pass freely over the entire battery surface and if possi ble so that the wind direction does not affect the evacuation air...

Page 6: ...duct is subjected to thorough inspection of quality and function before leaving the factory If faults or damage due to transportation are detected on the product the point of sale is to be contacted w...

Page 7: ...e used for starting and stopping Do not fit cable supports where they could damage the battery and thus cause leakage Tubing installation The product is to be filled with the amount and type of heat t...

Page 8: ...motor terminal box 5 The motor weighs 25 to 120 kg Lifting tackle is recommended 6 Unscrew the screws 6 that hold the motor 7 to the motor shelf 8 Lift out the motor Preventive maintenance 3 1 2 4 5 6...

Page 9: ...ive maintenance Warning Make certain that the power supply is disconnected Cleaning the cooling battery 1 Remove the service cover 1 2 Cooling batteries that are lightly soiled can be cleaned by brush...

Page 10: ...120 11 Dry Cooler Type DXP100 120 Air Cooled Condenser Type DCP100 Asarums IndustriAB Tel 46 454 334 00 S dra Industriv gen 2 4 Fax 46 454 320 295 SE 374 50 Asarum Sweden Lifting instruction 1900 mm 3...

Page 11: ...LU VE Sweden AB Tel 46 454 334 00 S dra Industriv gen 2 4 Fax 46 454 320 295 SE 374 50 Asarum Sweden 11 Dry Cooler Type DXP120...

Page 12: ...LU VE Sweden AB Tel 46 454 334 00 S dra Industriv gen 2 4 Fax 46 454 320 295 SE 374 50 Asarum Sweden 12 Dry Cooler Type DXP120 2015 04 17...