installation manual 

3. Wall Mounting Installtion 

2. Ceiling Installation 

Fig.5-8

   Locate the hanging arm on the hanging screw bolt. 

   (Refer to Fig. 5-9)      

    

Screw nut

Washer

Hanging

screw bolt

Hanging arm

Fig.5-9

20

25mm

Fig.5-7                                                                   

STEEL ROOF BEAM STRUCTRUE 

Hanging screw bolt

Hanging 

bolts

Supporting

 angle steel

Install and use directly the supporting angle steel. 

2     Install the indoor unit. 

Fig.5-4

Fig.5-5

Fig.5-6

Fig.5-7

NEW CONCRETE BRICKS  

FOR ORIGINAL CONCRETE BRICKS   

Steel bar

Embedding screw bolt

(Pipe hanging and embedding screw bolt) 

(Blade shape

 insertion)

(Slide insertion)

Inlaying or embedding the screw bolts. 

Install the hanging hook with expansible bolt into the concrete 
deep to 45~50mm to prevent loose. 

   Remove the side board and the grille.

(Refer to Fig. 5-8)  

Side board

Grille 

Hanging arm

Hanging

screw bolt

20mm 

The dimension of the unit 

5.3 

Table 5-1

6.1   Installation Place 

6.    OUTDOOR UNIT INSTALLATION 

The outdoor unit should be installed in the location that 
meets the following requiements: 

unit

mm 

 Fig. 5-10 

 Fig. 5-11 

 Fig. 5-12 

D. Connecting point of 

refrigerant pipe

(D.gas side)

Drain point

Downward declicity lower between(1-2)/100

E. Connecting point of 

refrigerant pipe
(E. Liquid side)

There is enough room for installation and maintenance. 

The air outlet and the air inlet are not impeded, and can 
not be reached by strong wind. 

It must be a dry and well ventilating place. 

The support is flat and horizontal and can stand the 
weight of the outdoor unit. And will no additional noise or 
vibration. 

Your neighborhood will not feel uncomfortable with the 
noise or expelled air. 

It is easy to install the connecting pipes or cables. 

Determine the air outlet direction where the discharged 
air is not blocked. 

There is no danger of fire due to leakage of inflammable 
gas. 

MODEL 

30~48

18~24

A B 

D E 

1068 675  235 983 

60

220 

675 

235 1565 

1650 

 

 

220 

1285 675  235 1200 220 

36~48

220 

675 

235 1565 

1650 

Summary of Contents for Ceiling Type

Page 1: ...Ceiling And Floor Type INSTALLATION MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference...

Page 2: ...ction of the fluid flow For electrical work follow the local national wiring standard regulation and this installation instructions An independent circuit and single outlet must be used If electrical...

Page 3: ...not be sufficient enough to eliminate the noise The appliance is not intended for use by young children or infirm persons without supervision Don t install the air conditioner in the following circums...

Page 4: ...me spare fittings please restore them carefully QUANTITY SHAPE NAME 5 Owner s manual 6 Installation manual 7 Remote controller manual 1 Remote controller on some models 2 Remote controller holder on s...

Page 5: ...When handling the unit take into account the following Fragile handle the unit with care Keep the unit upright in order to avoid compressor damage Choose on before hand the path along which the unit...

Page 6: ...Table 5 1 6 1 Installation Place 6 OUTDOOR UNIT INSTALLATION The outdoor unit should be installed in the location that meets the following requiements unit mm Fig 5 10 Fig 5 11 Fig 5 12 D Connecting...

Page 7: ...outdoor unit The condensate should be well drained away by the drain hole to an appropriate place so as not to interfere other people Select the position where it will not be subject to snow drifts a...

Page 8: ...ODEL A B C D E H REMARK F 24 18 30 36 845 560 335 360 312 700 320 900 590 333 355 302 860 315 990 624 366 396 340 965 345 990 624 366 396 340 965 345 990 624 366 396 340 965 345 990 624 366 396 340 96...

Page 9: ...6 15 Fasten the feet of this unit with bolts firmly to prevent it from collapsing in case of earthquake or strong wind Refer to Fig 6 15 NOTE NOTE Four different configuration are available for oudoo...

Page 10: ...unit No Description Outdoor Unit Vibration proof rubber Anchor Bolt M10 Drainage Wide 100 Depth 150 Drainage Mortar Hole 100 Depth 150 Sling Bolt Suspension Bracket Table 6 4 Table 6 5 Fig 6 17 MODEL...

Page 11: ...akage Please determine the torque according to Table 7 2 After the connecting work is finished be sure to check that there is no gas leak When connecting the flare nut coat the flare both inside and o...

Page 12: ...rge hose with the vacuum pump Open the Lo lever of the manifold value completely Turn on the vacuum pump At the beginning of pumping loosen the maintenance nut of stop valve B a little to check whethe...

Page 13: ...s position is shown figure below Drain Piping Fig 8 2 Fit the seal into the drain joint then insert the drain joint into the base pan hole of outdoor rotate 900 to securely assemble them Connect the d...

Page 14: ...Whether the generated wind noise or condensed of by the air conditioner have influenced your neighborhood c Whether any of the refrigerant is leaked A protection feature prevents the air conditioner...

Page 15: ...1Phase 208 240V 1Phase MODEL POWER CIRCUIT BREAKER FUSE A PHASE FREQUENCY AND VOLT 30 36 30 36 42 60 42 60 380 420V 25 20 25 20 40 25 45 35 208 240V 3Phase 380 420V 3Phase 3Phase 208 240V 3Phase Tabl...

Page 16: ...0 36 30 36 42 60 42 60 380 420V 25 20 25 20 40 25 45 35 208 240V 3Phase 380 420V 3Phase 3Phase 208 240V 3Phase Table 9 5 Table 9 6 PHASE FREQUENCY AND VOLT POWER indoor POWER outdoor 30 20 30 20 40 30...

Page 17: ...er wiring indoor Power linking wiring Outdoor Strong elec signal link wiring Weak elec signal link wiring Indoor Unit Outdoor Unit Ground the air conditioner properly in case to affect its anti interf...

Page 18: ...in all active conductors should be incorporated in the fixed wiring according to the National Wiring Regulation When wiring please choose the corresponding chart or it may cause damage The signs of th...

Page 19: ...tallation manual QSDLI 016AEN The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details 202000192522 20...

Page 20: ...19 installation manual...

Page 21: ...20 installation manual...

Page 22: ...21 installation manual...

Page 23: ...22 installation manual...

Page 24: ...33...

Page 25: ...34...

Reviews: