Page 1: ...Installation Quick Start Guide for SprayLogger E3 Last Update February 16 2018 ...

Page 2: ...ing online maps and sharing exported files Accessing these features over data network services may incur costs from your provider If you use the app and data services on your tablet you are responsible for any fees that your service provider charges Your service provider is not the provider of MapItFast AgTerra Technologies makes no representations expressed or implied as to data accuracy complete...

Page 3: ... Installation 4 Plumbing Wiring Switches Installation 7 Unit Setup 8 Connect to Device 8 Pair with Bluetooth MapItFast App 8 Download lists Connect unit Update flow meter s Start Spray Job 11 Enter job information Verify data recording TABLE OF CONTENTS ...

Page 4: ... C GPS Antenna D Power Cable E Switch Port Cable one for each enabled switch port F Flow Sensor Cable Yellow 6 C Installation Components The following items are generally included in a shipment however some components may look different than those pictured and or additional items may be included Refer to your packing slip for a detailed list of all items included in your shipment NOTE ...

Page 5: ...icles settling out PLEASE READ THE OPERATING MANUAL INCLUDED WITH YOUR SENSOR This quick start guide only provides an overview To avoid false readings and contamination mount the flow sensor in the lowest possible position relative to the tank in a vertical position flow going UP If this is not possible install in such a way that back washes or bubbles are minimized See diagram BEST RISK OF CONTAM...

Page 6: ...UMBING 3 C Cable for Switch 3 pin Brown not used Black ground Blue power Power Flow Sensor Check valve is not required when SprayLogger is used in combination with a switch Check valves help prevent false readings from air bubbles or inadvertent fluid movement Check Valve optional Install the backflow preventer check valve before or after the flow meter This will help prevent false flow readings f...

Page 7: ...erative that the GPS antenna cable and flow sensor cables and equipment wiring are installed away each other and from other electrical wires and engine components on the vehicle otherwise false readings will result o If two VMZs are installed next to each other make sure they are at least 2 inches apart Otherwise they may interfere with each other o Your SprayLogger is water resistant but not wate...

Page 8: ... is too short longer cables are available from AgTerra 1 If your SprayLogger E3 includes optional switch channels use the 3 C yellow cable s included in your shipment See the wiring diagram on the next page for additional information Switches Installation Note the cables for the flow sensors and switches look alike as do their ports on the SprayLogger box Unless you have a custom configuration flo...

Page 9: ...8 ...

Page 10: ...few seconds once you start a spray job in the MapItFast app The blinking light indicates that your box has a GPS signal If the light does not begin blinking within two minutes of powering on the box try rebooting the SprayLogger unit by powering it off and back on again You will first need to pair your device with your SprayLogger 1 Find Bluetooth settings on your mobile device 2 Available devices...

Page 11: ...screen a If the menu is not visible go to MapItFast Settings SprayLogger Show SprayLogger UI b Both SprayLogger windows can be expanded using arrow buttons on bottom and side of MapItFast screen c Tap on the settings button on the lower SprayLogger menu to get the latest lists from the server You must be connected to the internet for this step MapItFast App ...

Page 12: ...ated by your administrator 2 From the list of SprayLogger units tap the unit you would like to connect to Then tap the Connect button The button will change from Connect to Disconnect You are now connected to your SprayLogger unit via Bluetooth Note if you temporarily lose or have intermittent connection with the box the menu may blink or turn yellow If you completely lose connection it will turn ...

Page 13: ... will need to update the flow meter settings To do this tap the settings button again 4 Select Totals Reprogramming in the menu 5 In the next window select Reprogram Unit from Cloud 6 Your SprayLogger unit is now ready to start recording a spray job ...

Page 14: ...tFast app section 3 You have now connected your SprayLogger unit and started a job Observe the pulse readings to confirm that the flow sensor detects flow when you spray Note It is normal to see occasional random pulses even when you are not actively spraying These pulses however should NOT be sufficient enough to record a volume of spray If they do check for proper installation you may need a bac...

Page 15: ...creen by tapping the menu arrows When the menu is minimized it will display the total gallons sprayed for your job your vehicle speed acres miles or hectares kilometers sprayed and weather temp wind speed humidity wind direction Note If you have an Internet connection weather readings will be obtained from the nearest weather station each hour If the weather in your working area differs or you do ...

Page 16: ...ine help guide after logging into your account at https spraylogger agterra com or contact your local dealer or AgTerra office Thank you for using our products We would love to hear from you Contact us at support agterra com or call us at 1 866 408 2675 ...