AgSense CROP-LINK Wiring Manual Download Page 1

 
 

 
 
 
 
 
 
 
 

 
 
 
 

 
 
 
 

2011-16 Crop Link 

Flowmeter Wiring Manual 

 

 

Revised January 1, 2017 

 

 
 
 
 
 
 
 

Summary of Contents for CROP-LINK

Page 1: ...2011 16 Crop Link Flowmeter Wiring Manual Revised January 1 2017 ...

Page 2: ...ge 15 16 Siemens MAG5000 Flow Meters Page 17 19 Seametrics PE102 FT520 Flow Meter Wiring Page 20 22 GF Signet 9900 Flow Transmitter Wiring Page 23 24 GF Signet 2551 Mag Meter Wiring Page 25 McCrometer FlowCom Flow Meter Wiring Page 26 27 McCrometer McMag 3000 EA 618 Flow Meter Wiring Page 28 29 Siemens Sitrans FM MAG 8000 Wiring Page 30 32 Greyline AVFM 5 0 Flow Meter Wiring Page 33 34 Senninger F...

Page 3: ...General Overview of the Crop Link Unit Page 1 ...

Page 4: ...tall the Black Wire from the Netafim Dwyer Flow Meter into any terminal marked GND as shown in the picture above 2 Install the Red Wire from the Netafim Dwyer Flow Meter into the terminal marked FLW INT1 as shown in the picture above 3 Proceed to Page 42 of this manual for power wire connections Page 2 ...

Page 5: ...er into the terminal marked FLW INT1 as shown in the picture above 3 Cut off and or tape off the Green Wire from the Netafim Flow meter so that it cannot touch anything 4 The label on the inside of the Netafim Flow Meter lid will show how many gallons per pulse that output1 the red wire is programmed to do You will need that info when configuring this unit on Wagnet 5 Proceed to Page 42 of this ma...

Page 6: ...ers 1 Install the Black Wire from the GF Signet Flow Meter into the terminal marked 5v OUT as shown in the picture above 2 Install the White Bare Wire from the GF Signet Flow Meter into any terminal marked GND as shown in the picture above 3 Install the Red Wire from the GF Signet Flow Meter into the terminal marked FLW INT1 as shown in the picture above 4 Proceed to Page 42 of this manual for pow...

Page 7: ...he GF Signet 8550 Unit as shown above 2 Install a Red wire into terminal 5 output of the 8550 Unit as shown above This wire will connect to the AgSense unit in the steps below 3 Install a Black wire into terminal 6 output of the 8550 Unit as shown above This wire will connect to the AgSense unit in the steps below Page 5 ...

Page 8: ...tall the Red Wire from the GF Signet 8550 Flow Transmitter into the terminal marked FLW INT1 as shown in the picture above 3 Setting up the 8550 Flow Transmitter calibrate and options menus use the charts below to correctly set up the menus in the 8550 Flow Transmitter you must do this for the AgSense unit to work properly Page 6 ...

Page 9: ...Page 7 ...

Page 10: ...Page 8 ...

Page 11: ...Once these settings are all changed proceed to page 42 for AgSense Unit power connections Page 9 ...

Page 12: ...l marked 12v OUT as shown in the picture above 2 Install the Black Wire from the McCrometer Flow Meter into any terminal marked GND as shown in the picture above 3 Install the Orange Wire from the McCrometer Flow Meter into the terminal marked FLW INT1 as shown in the picture above 4 Proceed to Page 42 of this manual for power wire connections Page 10 ...

Page 13: ...Wire Connections for the Seametrics AG2000 Flow Meter Page 11 ...

Page 14: ...he terminal marked 12v OUT as shown in the picture above 2 Install the Black Wire from the Seametrics Flow Meter into any terminal marked GND as shown in the picture above 3 Install the White Wire from the Seametrics Flow Meter into any terminal marked GND as shown in the picture above 4 Install the Green Wire from the Seametrics Flow Meter into the terminal marked FLW INT1 as shown in the picture...

Page 15: ...Wire Connections for the Endress Hauser Promag P 50 53 Series Flow Meter 120v powered meter shown meter must be ordered the correct type with terminals 24 and 25 setup as Frequency Output pulses Page 13 ...

Page 16: ...rked FLW INT1 as shown in the picture above 3 Using the menu on the EH flowmeter be sure that the display of the flowmeter is set to gallons per minute Then using the menu on the EH flowmeter set the pulse output to 10 gallons per pulse you will need to enter that info in the crop link config page later 4 Proceed to Page 42 of this manual for power wire connections Page 14 ...

Page 17: ...Wire Connections for the Siemens MAG5000 Series Flow Meters 120v powered meter shown In the Siemens MAG5000 Menu you must make sure the following is set Page 15 ...

Page 18: ...inal marked GND as shown in the picture above 2 Install the Red Wire from the Siemens Flow Meter into the terminal marked FLW INT1 as shown in the picture above 3 Set the Config on Wagnet for this unit to Siemens and 10 gallons per pulse 4 Proceed to Page 42 of this manual for power wire connections Page 16 ...

Page 19: ...T520 Display PE102 Flow Meter Connect the PE102 Flow Meter the AC Power and a cable to the Crop Link unit as shown Use the SET button and the arrows on the FT520 display to change the flow rate to Gallons per Minute as shown below Page 17 ...

Page 20: ...he SET button and the arrows on the FT520 display to set the K FACTOR as shown below use the actual K Factor in the documentation for your specific flow meter the number below is only an example Use the SET button and the arrows on the FT520 display to set the Pulse Output to the correct scale as shown below Page 18 ...

Page 21: ...nal marked FLW INT1 as shown in the picture above 2 Install the Black Wire from the Seametrics FT520 into any terminal marked GND as shown in the picture above 3 Set the Config on Wagnet for this unit to SeaMetrics PE102 FT520 and 100 pulses per gallon Proceed to Page 42 of this manual for power wire connections Page 19 ...

Page 22: ...gnet 9900 settings Hold down the Enter button for more than 3 seconds to enter the settings menus When asked for a password or code the default is INPUT MENU 1 Set the sensor TYPE to FLOW 2 Set the sensor NAME to FLOW 3 Set the SENSITIVITY to 100 if using with small flow meters this number may need to be set lower see GF Signet 9900 Manual Page 20 ...

Page 23: ...MENU The RELAY menu enables the open collector OC OC output to send pulse data to the Crop Link unit The Relay 1 settings are what turns on the Open Collector output change the settings as follows 1 Set R1 to NORMAL OPEN 2 Set R1 MODE to VOL PULS 3 Set R1 VOLUME to 10 00 4 Set R1 PULSE WIDTH to 0 1 5 Press the and arrows at the same time to exit this menu 6 Press the and arrows again at the same t...

Page 24: ...erminal marked FLW INT1 as shown in the picture above 2 Install the Black Wire from the GF Signet 9900 into any terminal marked GND as shown in the picture above 3 Set the Config on Wagnet for this unit to GF Signet 8550 9900 and 10 pulses per gallon Proceed to Page 42 of this manual for power wire connections Page 22 ...

Page 25: ...e the jumper shown above is in place for this meter to output frequency 2 Install a black wire into terminal 1 5v input in the 2551 Mag Meter 3 Install a red wire into terminal 2 pulse output in the 2551 Mag Meter 4 Install a white wire into terminal 3 ground in the 2551 Mag Meter Page 23 ...

Page 26: ...5v OUT as shown in the picture above 2 Install the White Wire from the GF Signet Mag Meter into any terminal marked GND as shown in the picture above 3 Install the Red Wire from the GF Signet Mag Meter into the terminal marked FLW INT1 as shown in the picture above 4 Proceed to Page 42 of this manual for power wire connections Page 24 ...

Page 27: ...GND as shown in the picture above 2 Install the Bare Wire from the McCrometer Flow Meter into any terminal marked GND as shown in the picture above 3 Install the White Wire from the McCrometer Flow Meter into the terminal marked FLW INT1 as shown in the picture above 4 Proceed to Page 42 of this manual for power wire connections Page 25 ...

Page 28: ...Wire Connections for the McCrometer McMag 3000 Or EA 618 02 Flow Meters Page 26 ...

Page 29: ...from the McCrometer Flow Meter into the terminal marked FLW INT1 as shown in the picture above 3 Proceed to Page 42 of this manual for power wire connections 4 On the wagnet website Config Tab select McMag3000 from the Digtal 1 Flow selection and set the gallons per pulse of this flow meter to 100 this is the normal amount set by the factory when the flow meter was manufactured Page 27 ...

Page 30: ...l go to the Crop Link Unit 2 Install a Black wire into terminal 57 of the flow meter This wire will go to the Crop Link Unit 3 Also install a jumper wire into terminal 57 of the flow meter and connect the opposite end of the wire to one of the metal screws on the brackets that support the circuit boards inside the flow meter Page 28 ...

Page 31: ... Black Wire from the Sitrans Flow Meter into any terminal marked GND as shown in the picture above 2 Install the Red Wire from the Sitrans Flow Meter into the terminal marked FLW INT1 as shown in the picture above 3 Proceed to Page 42 of this manual for power wire connections Page 29 ...

Page 32: ... of the flow meter This wire will go to the Crop Link Unit 2 Install a Black wire into Relay 1 Common terminal of the flow meter This wire will go to the Crop Link Unit 3 Make sure the Menu Settings have been set to Gallons Per Minute and Relay 1 set for pulse output as shown in the photos on the next page Page 30 ...

Page 33: ...lay 1 is setup for Pulse operation and set the gallons per pulse 10 gallons per pulse shown above Depending on the size of pipe channel that you are measuring you will want to set the Gallons per pulse to a larger 10 0 Small Pipe less than 100 GPM 100 0 Medium Pipe 100 1000 GPM 1000 0 Large Pipe 1000 GPM Page 31 ...

Page 34: ... Wire from the Greyline Flow Meter into any terminal marked GND as shown in the picture above 2 Install the Red Wire from the Greyline Flow Meter into the terminal marked FLW INT1 as shown in the picture above 3 Proceed to Page 42 of this manual for power wire connections Page 32 ...

Page 35: ...consult your flo wise instruction manual for flow meter wiring variations 2 Install the DC power supply to terminals 7 and 8 as shown above 3 Install the pair of wires from the Crop Link unit to terminals 9 and 10 as shown above 4 Configure the SC 3 Pulse Output in the SC 3 menu to output a pulse every 100 gallons Page 33 ...

Page 36: ...above 2 Install the Red Wire from the SC 3 Flow Meter into the terminal marked FLW INT1 as shown in the picture above 3 Proceed to Page 42 of this manual for power wire connections 4 On the Crop Link unit config page choose GF Signet 8550 9900 SC 3 in the Digital 1 Options section and enter 100 gallons per pulse Then click Save Config at the bottom of the page Page 34 ...

Page 37: ...n above not supplied by AgSense 2 Install the 4 Ground wires from the flow meter and the Ground wire from the Crop Link unit into a wire nut with the wire from the DC power supply as shown above all grounds connected together 3 The Blue pulse output wire from the flow meter goes to the Crop Link unit 4 See the next page for Crop Link wiring Page 35 ...

Page 38: ...rom the Flow Meter into the terminal marked FLW INT1 as shown in the picture above 3 Proceed to Page 42 of this manual for power wire connections 4 On the Crop Link unit config page choose Banjo in the Digital 1 Options section and enter 13 Pulses per gallon high frequency meters or 1 pulse per gallon standard frequency meters Then click Save Config at the bottom of the page Page 36 ...

Page 39: ...s FT415 Flow Meter 1 Install a Red wire into the Pulse Scaled terminal of the flow meter This wire will go to the Crop Link Unit 2 Install a Black wire into Pulse Scaled of the flow meter This wire will go to the Crop Link Unit Page 37 ...

Page 40: ...d Wire from the FT415 Flow Meter into the terminal marked FLW INT1 as shown in the picture above 3 Make sure the flow meter display P menu is setup for 1 10 0r 100 gallons per pulse depending on pipe size smaller pipe 1 large pipe 100 4 Set the Crop Link configuration to the same gallons per pulse as set in step 3 5 Proceed to Page 42 of this manual for power wire connections Page 38 ...

Page 41: ...er 1 Install a Black wire into the Tiger Mag Flow Meter into the terminal marked OPEN COLLECTOR as shown in the picture above 2 Install a Red wire into the Tiger Mag Flow Meter into the terminal marked OPEN COLLECTOR as shown in the picture above Page 39 ...

Page 42: ...u will enter this same number 10 or 100 on the CommanderVP Config page in the Gallons Per Pulse section Set Outputs menu Empty Pipe Detection EPD 5 this is just a starting point these meters default to EPD 0 and thus will count some flow when the pipe is empty so need to start with 5 and adjust from there to see what works best refer to the Tiger Mag manual for more information CommanderVP Unit Co...

Page 43: ...Wire from the Tiger Mag Flow Meter into any terminal marked GND as shown in the picture above 2 Install the Red Wire from the Tiger Mag Flow Meter into the terminal marked FLW INT1 as shown in the picture above 3 Proceed to Page 42 of this manual for power wire connections Page 41 ...

Page 44: ...r unit Call AgSense at 605 352 8350 to have the configuration sent to the unit so it will start to read the flow meter Also once power is applied to our unit the configuration has been sent to the unit and water is flowing through the pipe the GPS light in the upper right corner of our circuit board will be blinking Optional This unit has 2 relays that can be used to via the website to remotely co...

Page 45: ...t satisfied with product 1 Year Repair on any unit that fails due to defect in materials or workmanship AgSense labor and parts would be provided free of charge during the warranty period This does not include dealer labor What is not covered Service trips to your home to teach you how to use the product Improper installation delivery or maintenance If you have an installation problem contact your...

Page 46: ...nd all responsibility for the reliability of this technology Customer acknowledges that AgSense does not have the ability to control the reliability of GPS Satellite and Internet Technology AgSense specifically disclaims any and all liability for Customer s failure to personally determine whether or not the irrigation equipment that belongs to Customer is functioning properly AgSense its agents me...

Page 47: ......

Page 48: ...AgSense LLC 259 Dakota Ave S PO Box 53 Huron SD 57350 605 352 8350 www AgSense net ...