background image

 

11

 
 
The  fertilization  status  for  each  line  is  shown  with  an  arrow  ( 

  )  provided  that  there  is  fertilizer’s  flow.  In 

contrast, if an adequate flow is not detected, the corresponding line will be displayed in red ( 

 ) and an alarm 

will be activated (details on Page. 22). 

In  order  to  get  an  optimum  graphic  viewing,  the  Pipes  tab  will  display  39  pipes 
simultaneously  as  maximum. In case of more than  39 rows are  being monitored, they will 
be distributed in other pages. To go to a different page press the key corresponding to the 
tab Pipes as many times as necessary.   

 

 

Summary of Contents for AGFusion

Page 1: ......

Page 2: ...s per meter that will be through in every row modifying the Density Seed value Page 20 The computer has a protection fuse of 5 A amperes in its power cable near to terminals that are connected to the...

Page 3: ...onto the pen drive 19 8 Seed and fertilization monitoring 20 8 1 Seed density failure 20 8 1 2 How to change seed density and tolerance 21 8 1 3 How to Enable Disable Seed Density Monitoring 21 8 2 Se...

Page 4: ...and fertilizer sensor status o Audible and displayed failures as follows Seed Density Failure incorrect value of the number of seeds planted per row Seed Failure seeds falling are not detected in pipe...

Page 5: ...tributes ordered correctly The first attribute corresponds to Linear Fertilizer in Kg Ha the second one corresponds to Alongside Fertilizer in Kg Ha and the third one to seeds every 10 meters o It all...

Page 6: ...in menu computer s data and configuration only for authorized users o Installer s security code to avoid activating any non desired function The critical functions are the ones which allow saving the...

Page 7: ...hen Job Screen will appear as in Figure 1 Here different parts or areas with a particular type of information are presented Next each of these areas is described in more detail Figure 1 Job Screen 2 1...

Page 8: ...e by the pipes Linear Fertilizer Rate kg ha On the right of the box heading Fert L it is displayed the desired value and on the box is displayed the real value applied Alongside Fertilizer Rate kg ha...

Page 9: ...centage of available space onto the SD memory card where data is stored When mapping is disabled the symbol will be displayed Here there are two examples Selected plot 2 Mapping enabled Available spac...

Page 10: ...ensity limits allowed according to the programmed Seed Tolerance Page 20 For instance if the computer is configured with Seed Density of 10 S m seeds per meter and Seed Tolerance of 20 then the horizo...

Page 11: ...line will be displayed in red and an alarm will be activated details on Page 22 In order to get an optimum graphic viewing the Pipes tab will display 39 pipes simultaneously as maximum In case of more...

Page 12: ...level Sensor OK auto adjust high level Sensor disabled page 25 Sensor disconnected page 33 Sensor with wire in short circuit page 33 1 Auto adjust level In some occasions a blanket of agrochemical in...

Page 13: ...displays manual rate mode While in a job press the Rate key and select one of the four groups of rate preprogrammed previously In this case Rate1 setting is 110 Kg ha of Linear Fertilizer 95 Kg ha of...

Page 14: ...ty configuration enabling disabling of densities fertilization section a particular sensor monitoring or do a sensor testing 6 DISPENSER This option groups the functions of VRA system selection of aut...

Page 15: ...TOMATIC RATE SCREEN BACKLIGHT SETTING PROFILE SPEED LIMIT MAIN MENU INSTALLER SOPTIONS Details in Installation and Technical Assistance Guide JOB REGISTER MONITOR CLEAR PLOT CLEAR TOTALS MAPPING COPY...

Page 16: ...uration Fine crop and coarse crop the setting profiles according to the installation moment will be saved In this way the user can recover them at any time just selecting the desired profile in Settin...

Page 17: ...ber respectively If Job Mapping is activated the data is stored in a file named according to the number of the plot For example if plot number 2 is selected the text file where mapping will be saved i...

Page 18: ...EEDS ROW 1 DENSITY ROW 2 DENSITY LAST ROW DENSITY LATITUDE first column Latitude of the point in decimal degrees LONGITUDE second column Longitude of the point in decimal degrees TIME third column Mom...

Page 19: ...created A GPS receiver must be connected also because this one will provide positioning information on the plot 7 5 Job reports The computer will create a simple text file onto the SD card with job r...

Page 20: ...presentation as follows In this example a Seed Density of 12 s m seeds per meter per row and Tolerance of 10 was programmed In this way the tolerable seed values will be within 10 8 and 13 2 S m 12 S...

Page 21: ...seed density value To change this value select Seed Tolerance option from Monitor menu MENU MONITOR SEED TOLERANCE 8 1 3 How to Enable Disable Seed Density Monitoring If you want to disable seed densi...

Page 22: ...e Figure 13 displays a linear fertilization failure in row 5 and alongside fertilization failure in rows 9 and 10 Figure 13 Linear fertilization failure in row 5 and alongside fertilization failure in...

Page 23: ...Limit select that option in Main Menu MENU SPEED LIMIT 8 5 Shaft rotation failure Optional This failure will be activated when a monitored shaft stops rotation For example 8 6 Low level in hoppers Op...

Page 24: ...ed is modified when the sensor is activated many times In order to test a rpm sensor check that the value displayed is not zero in the corresponding box A hopper sensor is activated when an object is...

Page 25: ...s Next Node key to go to wiring configuration chart of the next node till localizes it Pressing Enable Yes No will modify its status Figure 15 displays the corresponding menu Figure 15 Enable or Disab...

Page 26: ...steps to follow for fertilizer L Linear calibration 1 Enter to Rate Calibration option in DISPENSER menu Figure 106 MAIN MENU DISPENSER RATE CALIBRATION Figure 16 Rate Calibration Screen 2 Select the...

Page 27: ...arrows or or down arrows to increase or to decrease the value respectively Then the computer will calculate the value that corresponds to 10 rounds exactly Figure 19 Figure 18 Fert L Rate Calibration...

Page 28: ...manually so calibration repetition is not necessary This correction has to be done only when a not correct applied average is detected easily If the real amount of the applied product is over the one...

Page 29: ...ys on the left hand side of the screen to and the arrow to the right Then pressing the arrows up and down the highlighted value will increase or decrease respectively Once all the rate values have bee...

Page 30: ...of polygons that determines the zones or areas with similar attributes A data base file dbf contains the prescript rate values associates to each area Thus the first attribute corresponds to linear Fe...

Page 31: ...being controlled with zero value for example 11 3 2 Automatic Variable Rate Mode Select Automatic Rate option in DISPENSER menu to initiate this mode Then the prescription selection will be displayed...

Page 32: ...described in 2 2 section on Page 8 This screen also presents the loaded prescription s name map s orientation always the north on the top the current implement s position on the plot its geographical...

Page 33: ...onnect them one by one till the error appears again In this way the node with problems will be indentified No connection with node Fert L Fert A Seed Monitor This message also indicates the node or no...

Page 34: ...in File error Open read close file is not possible Writing Reading file error Clear copy file is not possible These warnings appear when there is any problem in any drive file SD or pen drive It is re...

Page 35: ...lement s chassis The prescription should define less than 100 zones This message appears when trying to load a prescription map SHP that contains more than 10 areas on the same map It is suggested to...

Page 36: ...e computer It is suggested to check that each node has been configured correctly No numerical DBF field The dbf file s field does not have a numerical format It must contain 3 numerical fields FERT L...

Page 37: ...rface RS 232 Chassis Power wire and CAN bus Spearhead connection Node 1 Node 2 CAN bus Terminal AG FUSION Frontal view CAN bus Speed Sensor CVT 2 Sensor connectors CVT 1 CVT 3 Last CVT CAN bus AG FUSI...

Page 38: ......

Reviews: