7.9.4
Distribution cube and adjustable nozzle holders
Figure 7.10
•
The blower has two distribution cubes designed to distribute the flow to individual nozzles.
The air flow can be individually directed through the regulator and two valves to the first or
the other section (18/2). If the regulator has four valves, the flow can also be directed to four
sections (18/4).
•
The nozzle holders are connected to the distribution cube with a flexible hose. It is possible
to adjust the height and direction of nozzle holders.
7.9.5
Multiplier gearbox
The multiplier gearbox is used for the transmission of torque from the pump to the fan via the
flange. It provides two-speed transmission which can be disengaged to stop the rotation (fan
switch-off). The multiplier gearbox and the pump are connected by means of a flange. The
multiplier gearbox is lubricated with the SAE 90 oil. It can be checked thought the window (6 −
Figure 7.8) and added through the filler plug (3 − Figure 7.8).
Figure 7.11
SWITCH-OFF AND GEAR
CHANGING
The multiplier gearbox with a shaft that
propels the fan has a switch-off lever
mounted at the side that switches off the
rotation or speed level of the fan. This way
the mist blower can be used for other
purposes (preparing the spraying mixture,
mixing, spraying with a manual spraying
lance etc.).