AG-tronik M1 AND REGULATOR PR-9
INSTRUCTIONS FOR USE – rev. 2017-04
13
7. OPERATION DESCRIPTION
– MANUAL CONTROL
Spraying in manual control is done with settings, which are input manually. This enables to
increase or decrease pressure during work and therefore change liter per hectare. Spraying is
therefore done without a computer or without automatic regulation. With key
open the main valve and individual sections, and keys
are used to set work pressure. Pressure regulation with keys
is possible only when the
main central valve is turned on
.
If correct constants for speed sensor, flow sensor and working width are input in AG-tronik,
then we can monitor all main parameters of spraying on the display, such as:
liter per hectare
spraying speed
working width
treated area
hectare efficiency
travelled distance
current flow
Manual control can be implemented, when AG-tronik is turned on, key
is turned on
(red LED in the upper right corner of the key is turned on), and key
is turned off
(LED in the upper right corner of key AUTO is not turned on or does not blink).