INSTRUCTIONS FOR USE
AGS 1800 - 2000 EN-HV (HVB)
Rev.9/2018
114
REMEMBER:
•
it is sufficient to tighten the joint by hand (radial sealing);
•
it is sufficient to tighten the joint by a hand tool (axial sealing).
Figure 16.5
16.6.9
OTHER PARTS
The rest of the vital parts such as filter inserts, pouring sieve, additional equipment, etc. must be
thoroughly cleaned, checked and replaced if necessary, too. Remove the remaining water and eventual
sediments from parts such as suction filters and three-way valves. Grease all moving and sliding parts
of the sprayer.
To protect the appliance against cold, follow the instructions written below:
•
either remove all water from the pump, the regulator, the hoses, the filters and other elements
of the sprayer;
•
either store the appliance in a warm room;
•
or use an agent against freezing (antifreeze) in accordance with the following procedure:
After you have finished cleaning the spraying appliance, completely empty the reservoir and pour at
least 10 litres of antifreeze agent (a mixture of water and antifreeze) and turn on the pump. Open all
valves on the regulator in order the antifreeze agent can reach all hoses and nozzles.
At the end, empty the remaining agent from the reservoir into the tank and let the pump operate for
few more minutes in order to pump the remaining agent into the tank.
Protect the manometer against freezing by unscrewing it from the regulator and storing it in a warm
room. The manometer must be stored in an upright position or the glycerine filling can flow out.
WARNING: If the temperatures get below zero, protect the spraying appliance
against cold, which could damage it!
WARNING: Make sure that the antifreeze agent is poured into appropriate
containers! Do not discard antifreeze agents in nature!