7.2
RESERVOIR FOR RINSING
The reservoir for rinsing is intended for washing of the reservoir and other elements after you have
finished working or after a break. Fill the reservoir with clean water. You can find more detailed
instructions in the chapter 7.9.
7.3
RESERVOIR FOR WASHING HANDS
This reservoir is intended for washing hands after handling insecticides. Fill the reservoir with
drinkable water. Its capacity is 15 litres.
7.4
MIXING NOZZLE
To ensure better mixing, the sprayer is fitted with mixing nozzles, integrated into the bottom part of
the reservoir. The mixing nozzle is controlled by means of the diverter valve mounted on the pressure
regulator. The mixing nozzle is active when the lever of the diverter valve is positioned vertically and
vice versa. During the preparation of the spraying mixture and when driving to the field, it is
recommended that the mixing nozzle is in operation.
Figure 9: Mixing nozzle
7.5
SUCTION FILTER
The suction filter is mounted between the reservoir and the pump. Its function is filtering the
insecticide before it reaches the regulator. The size of the filter is 50 MESH.
7.5.1
CLEANING FILTER INSERT
Firstly, unscrew the yellow lever (3) on the filter cover (2) by turning it counter clockwise and pulling
it out. The valve mounted inside the filter will close the flow of the liquid from the main reservoir.
Unscrew the nut (5) from the filter cover and remove the cover and the filter insert (4). Clean the filter
insert and mount all parts back together in the reverse order.
When mounting the parts back together, make sure that the metal pin of the locking valve, which is
located at the extracted part (with a yellow lever) will be properly inserted, otherwise the filter will not
function properly.