5
Maintenance and Repair
Hydrostatic implement carrier agria 5900 Cyclone
59
Hydraulic oil cooler (only 23 HP)
After long periods of operation, the cooling sys-
tem can be obstructed with dust or plant particles.
Continuous operation with an obstructed cooling
system causes the gearbox to overheat, and can
damage the gearbox.
Check the oil cooler (C/21) before startup. Using
brush or compressed air, remove dirt and plant
debris if necessary.
Hydraulic hoses
•
Check for leaks, damage and ageing after
200
operating hours, at least
yearly
.
•
Replace hydraulic hoses after
6 years
. Use
only new (not older than 2 years) genuine
Agria hydraulic hoses.
High-pressurized hydraulic oil can pene-
trate your skin and cause severe injuries. Dan-
ger to life!
To avoid injuries, use suitable devices when
you try to locate leaks - specialized workshop!
Brake
•
Check smooth operation and efficiency of
brake pads and brake actuation after every
200
operating hours or at least yearly.
- agria-Service -
Wheel motors
•
Check for straightline driving at steering bar
neutral position every
200
operating hours.
- agria-Service -
Summary of Contents for Cyclone 5900
Page 4: ...4 agria 5900 Cyclone Designation of parts Fig A Fig B...
Page 22: ...2 Technical Data 22 Hydrostatic implement carrier agria 5900 Cyclone...
Page 80: ...80 Hydrostatic implement carrier agria 5900 Cyclone Petrol engine 23 HP...
Page 83: ...Hydrostatic implement carrier agria 5900 Cyclone 83 Declaration of Conformity...
Page 85: ...agria 5900 Cyclone 85 Fig C Petrol engine 14 HP...
Page 87: ...agria 5900 Cyclone 87 Fig D Petrol engine 23 HP...