HOW TO USE YOUR SPREADER

SETTING THE FLOW CONTROL

(Refer to figure 13 on page 7.)

1.

Loosen the nylon wing nut, set the adjustable stop to
the  desired  flow  rate  setting  and  retighten  the  wing
nut.  The  higher  the  setting  number,  the  wider  the
opening in the bottom of the hopper.

2.

Refer to the application chart on page 10 and to the
instructions on the fertilizer bag to select the proper
flow rate setting.

3.

Pull the flow control arm against the adjustable stop
for the on position and toward the hopper for the off
position.

OPERATION

USING YOUR SPREADER

We  do  not  recommend  the  use  of  any  powdered  lawn
chemicals,  due  to  difficulty  in  obtaining  a  satisfactory  or
consistent broadcast pattern.

1.

Determine approximate square footage of area to be
covered and estimate amount of material required.

2.

Before filling the hopper make sure the flow control
arm is in the off position and the closure plate is shut.

3.

Break up any lumpy fertilizer as you fill the hopper.

4.

Set the adjustable stop with the flow control arm still in
the off position. Refer to the application chart on page
10 and to the instructions on the fertilizer bag to select
the proper flow rate setting.

5.

The application chart is calculated for light to heavy
application at a walking speed of 3 mph, or 100 ft. in
23  seconds.  A  variation  in  speed  will  require  an
adjustment  of  the  flow  rate  to  maintain  the  same
coverage. The faster you walk, the wider the broad-
cast width.

6.

Always start the spreader in motion before opening
the closure plate.

7.

Always shut the closure plate before turning or stop-
ping the spreader.

8.

If fertilizer is accidentally deposited too heavily in a
small area, soak the area thoroughly with a garden
hose or sprinkler to prevent burning of the lawn.

9.

To insure uniform coverage, make each pass so that
the  broadcast  pattern  slightly  overlaps  the  pattern
from  the  previous  pass  as  shown  in  figure  17.  The
approximate broadcast widths for different materials
are shown in the application chart on this page.

10. When  broadcasting  weed  control  fertilizers,  make

sure  the  broadcast  pattern  does  not  hit  evergreen
trees, flowers or shrubs. Lower the spreader shield to
limit  the  dispersal  pattern.  Reduce  the  flow  control
setting according to the application chart on page 10.

FIGURE 17

APPLICATION DIAGRAM

11. Heavy moisture conditions may require a cover over

the  hopper  to  keep  contents  dry.  The  vinyl  cover
(available as an accessory) acts as a wind and mois-
ture shield, but should not be used as a rain cover.
Refer to the parts list on page 13.

OVERLAP

8’ to
 10’

OVERLAP

3’ to
 4’

SHIELD UP

SHIELD DOWN

Summary of Contents for 45-02103-101

Page 1: ...PUSH BROADCAST SPREADER PRINTED IN U S A FORM NO 49120 12 03 OWNERS MANUAL Model No 45 02103 101 Assembly Operation Maintenance Repair Parts the fastest way to purchase parts www speedepart com Agri F...

Page 2: ...lying lawn or garden chemicals 4 Read the chemical label instructions and cautions for handling and applying the chemicals purchased for spreading 5 Keep all nuts bolts and screws tight to be sure equ...

Page 3: ...Flat Washer 5 16 SAE G 8 Nylon Washer H 4 Flat Washer 5 8 I 1 Cotter Pin 5 32 x 2 J 1 Cotter Pin 3 32 x 3 4 Long KEY QTY DESCRIPTION K 1 Flow Control Link L 2 Spacer Tube M 2 Hub Cap N 1 Grip O 1 Viny...

Page 4: ...le a 5 32 x 2 cotter pin through the hole in the wheel hub and the axle See figure 3 7 Place a 5 8 flat washer onto the axle and then lightly tap a hub cap onto the axle until it is snug against the w...

Page 5: ...ace the long handle tube onto the crossover tube on the side opposite from the shaft support plate Fasten with the bolt washer and nut re moved in the previous step See figures 4 and 5 Do not tighten...

Page 6: ...od through the slot in the flow control mounting bracket and through the hole in the flow control link Secure with a 3 32 x 3 4 cotter pin See figure 9 20 Assemble both the flow control mounting brack...

Page 7: ...per just closes c Snug the 1 4 lock nuts just enough to hold flow control mounting bracket in place d Set adjustable stop at 5 Pull flow control arm against stop Verify that closure plate has opened a...

Page 8: ...4 x 1 hex bolt two 5 16 washers a nylon washer and a 1 4 Nylock nut Place the angle stop bracket on the inside and the swivel bracket on the outside Tighten the locknut so that the swivel bracket can...

Page 9: ...rt is calculated for light to heavy application at a walking speed of 3 mph or 100 ft in 23 seconds A variation in speed will require an adjustment of the flow rate to maintain the same coverage The f...

Page 10: ...FLOW SETTING SPREAD MATERIAL 3 MPH WIDTH 100 FT IN 17 SEC IN FEET APPLICATION CHART SHIELD DOWN FERTILIZER Powder 1 3 3 4 Granular 1 3 3 4 Pelleted 1 3 3 4 Organic 3 4 3 4 GRASS SEED Fine 1 3 3 4 Coar...

Page 11: ...tly apply automotive grease as needed to the sprocket and gear 6 Oil the nylon bushings on the vertical sprocket shaft and on the axle at least once a year or more often as needed 7 Oil right hand idl...

Page 12: ...20 33 25 38 26 36 31 49 17 35 35 B A D E D 16 14 27 48 37 37 43 44 34 41 42 8 11 11 45 39 50 50 23 23 15 15 21 28 28 29 32 40 40 9 9 9 9 9 9 9 9 9 7 7 7 7 7 7 9 29 21 21 32 21 A B 24 32 9 4 E 30 39 51...

Page 13: ...6 47441 1 Screen 57 24125 2 Shield Bracket 58 23999 2 Angle Stop Bracket 49120 1 Owner s Manual REF PART QTY DESCRIPTION NO NO 1 44466 1 Hopper 2 C 9M5732 2 Pop Rivet not shown 3 62482 1 Ass y Guide C...

Page 14: ...14...

Page 15: ...15...

Page 16: ...REPAIR PARTS Agri Fab Inc 303 West Raymond Sullivan IL 61951 217 728 8388 www agri fab com the fastest way to purchase parts www speedepart com...

Reviews: