User manual 

AGRETO three-point-scale  

Weighing indicator B400 

06 April 2017 

 

 

 

 

 

 

 

 

 

 

 

ATTENTION

ATTENTION

ATTENTION

ATTENTION! Read the operating instructions in this user manual before operating the 

equipment for the first time, in order to prevent damage to your scale or implement!

 

Summary of Contents for B300-V4-K342

Page 1: ...cs s s s G G G Gm m m mb b b bH H H H User manual AGRETO three point scale Weighing indicator B400 06 April 2017 ATTENTION ATTENTION ATTENTION ATTENTION Read the operating instructions in this user m...

Page 2: ...cable to the signal socket if available 14 6 7 Connecting the GPS speed sensor if available 15 6 8 Connecting the working position sensor if available 15 7 Weighing indicator 16 7 1 Switching on the...

Page 3: ...scope of delivery Standard scope of delivery Standard scope of delivery Steel construction with built in load cells 2 top link brackets with 160 mm hole spacing 2 top link brackets with 130 mm hole sp...

Page 4: ...nts with a total weight of 6 000 kg can be attached The scale must be set to the exact same mounting height as the attached implement The implement can only be connected to the scale via the two lower...

Page 5: ...h the AGRETO three point scale for the first time has read and understood this user manual 4 2 Safety guidelines for operating and assembling personnel Appropriate equipment must be used when employin...

Page 6: ...r pallet can slip on the vehicle Transport and loading personnel must be instructed to securely attach loads Be aware of the risk of crushing between the three point scale s moving parts during mounti...

Page 7: ...8 4mm 51 mm width or a CAT II Walterscheid quick coupling hook Lower link distance CAT II standard 87 5 cm can be adjusted infinitely between 85 and 90 cm with set screws can be adjusted manually up t...

Page 8: ...terproof Operating temperature 35 up to 65 C Temperature compensated 10 up to 40 C Weighing indicator Weighing indicator Weighing indicator Weighing indicator 6 digit LED backlit LCD display with 20 m...

Page 9: ...lug for cigarette lighter and standard sockets according to DIN EN ISO 4165 with integrated and replaceable fuse Accuracy Accuracy Accuracy Accuracy 0 02 load cell accuracy 1 to 2 accuracy when operat...

Page 10: ...ustment screws on both sides of the three point scale to keep the construction symmetrical Set the scale s width in such a way that there s a little space left between scale and implement so that the...

Page 11: ...any load from the scale Slightly loosen the nuts and use a rubber hammer to shift the brackets ATTENTION The exact setting of mounting height is not only a prerequisite for ATTENTION The exact setting...

Page 12: ...the brackets with 160 mm hole spacing If vertical mounting isn t possible the scale must be calibrated to obtain correct results Deviations are hardly noticeable when under 5 degrees in comparison to...

Page 13: ...mbH electronics GmbH electronics GmbH page page page page 13 13 13 13 The weighing signal cable is assigned as follows Front view cable socket Front view cable plug on the scale on the connecting cabl...

Page 14: ...magnets at 5 mm As soon as the sensor is correctly installed and connected the weighing indicator will display the driving speed in 10 second intervals To check the driving speed the working position...

Page 15: ...eighing indicator 6 8 Connecting the working position sensor if available The sensor has a red cap and the cables are marked red near the plug connectors The working position sensor tells the weighing...

Page 16: ...scale s actual load based on the most recently set zero point The upper larger line displays the scale s actual load for instance 865 kg and the lower smaller line displays the spread rate per hectare...

Page 17: ...e the amount of material which is scattered to a part of a field Press the TARE button at the beginning The indicator shows 0 and displays the NET symbol Continue with your work on the display you see...

Page 18: ...right away Proceed as follows to change other relevant settings Simultaneously keep the lower buttons on the far right F3 and far left the small one pressed for 3 seconds Wait until the word GEN OPT a...

Page 19: ...pulses you enter the number with the numeric keypad and confirm by pressing the OK button By pressing the TARE button the next parameter WIDTH appears Enter the working width in m with the numeric key...

Page 20: ...interval the difference in weight between the interval s average weight and the preceding interval s average weight is calculated This difference is then set off against the completed area distance d...

Page 21: ...anual mode Manual mode Manual mode In manual mode you can determine the start and end of calculation intervals yourself This allows calculations during a longer period for instance an entire field len...

Page 22: ...utton when the end of a track has been reached or else the U turn is also recorded and distorts the result For the same reason a new cycle must be started at each new track by pressing the F1 button M...

Page 23: ...RANGE 20 20 zeroing up to 20 of maximum load SCALE CAL SPAN 2667 calibration value at 0 8 mV 7 9 Calibration When the AGRETO three point scale is operated vertically or with a slight slant forward or...

Page 24: ...fined Wait until it says Done on the lower line Press the OK button ZERO appears on the display Press the GROSS NET button SPAN appears on the display Press the OK button twice Now put a load on the s...

Page 25: ...w up key on the right of the indicator until NUM ITEMS appears on the lower line This sets up the indicator in such a way that all sums appear on the display Press the OK button on the numeric keypad...

Page 26: ...re displayed As soon as this amount increases the summing function has been performed 7 10 3 Retrieving the sum To display the sum keep the 4 key secondary function total pressed for approx 2 seconds...

Page 27: ...educe load ERROR MOTION A ZERO ZERO ZERO ZERO or TARE TARE TARE TARE command can t be executed because the scale is unstable Try again when the scale is stable FAILED TOO CLOSE The difference between...

Page 28: ...ation of a few degrees doesn t matter that much Calibrate the scale Follow the instructions in this manual chapter 7 10 Unsatisfactory weighing results can be caused by tensions in the scale s suspens...

Page 29: ...weight in the back you must shift the two mounting parts slightly upwards You do not have to remove the scale Loosen the 4 internal nuts of the mounting screws and tap the bottom of the sliding mount...

Page 30: ...apply to the AGRETO three point scale AGRETO electronics GmbH guarantees proper functioning and repairs or replaces all parts that exhibit material or manufacturing defects during the warranty period...

Page 31: ...ulated in the Council Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility 2004 108 EG The evaluation of this product was carried out in accordance...

Page 32: ...ste Detailed information can be found in Directive 2002 96 EG 13 Contact information All information specifications and images in this manual are correct according to the status in 2017 and subject to...