J5 – In-Out
Figure
61
This connector carries all the input and output signals to remote control the
TPS-compact.
It is a 15-pins D type connector; the available signals are detailed in the table, the
following paragraphs describe the signal characteristics and use.
Table 4
Pin N.
Signal name
Input/Output
1 START/STOP
(+)
IN
2 START/STOP
(-)
IN
3
ADAPTIVE SCROLL DRIVING DISABLE (+)
IN
4
ADAPTIVE SCROLL DRIVING DISABLE (-)
IN
5 SPEED
SETTING
(+)
IN
6 SPEED
SETTING
(-)
IN
7
SOFT START (+)
IN
8
SOFT START (-)
IN
9
+24 Vdc Imax = 30 mA
OUT
10
NORMAL OUTPUT (relay contact)
Vmax = 125V
Imax = 200 mA
OUT
11
PROGRAMMABLE SET POINT
OUT
12
NORMAL OUTPUT (relay contact)
OUT
13 FAULT
OUTPUT
OUT
14
PROGRAMMABLE ANALOG SIGNAL (+)
OUT
15
•
GROUND
•
PROGRAMMABLE ANALOG SIGNAL (-)
OUT