![Agilent Technologies N9010A Manual Download Page 32](http://html1.mh-extra.com/html/agilent-technologies/n9010a/n9010a_manual_2868178032.webp)
32
Chapter 4
Power vs. Time Measurements
Measurement Procedure
Measurement Procedure
Step 1.
Press
Mode
,
TD-SCDMA with HSPA/8PSK
to enable the TD-SCDMA with
HSPA/8PSK mode measurements.
Step 2.
Press
Mode Preset
to preset the analyzer.
Step 3.
Press
Input/Output
,
External Gain
,
BTS
and enter the number and
−
dB
according to the external attenuator connected to the analyzer.
Step 4.
Press
Mode Setup
,
Radio
,
Device
to toggle the device to
BTS
.
Step 5.
Press
Trigger
to select the appropriate trigger source
External 1
.
If no measurement is performed and only a symbol of yellow ‘*’ displays
on the top right of the screen, you need to check the trigger settings.
You need the correct trigger signal to make the Power vs Time
measurement.
Step 6.
Press
FREQ Channel
,
2
,
GHz
to set the center frequency to 2 GHz.
Step 7.
Press
Meas
,
Power vs Time
to initiate the Power vs Time measurement.
Step 8.
Press
Restart
or
Single
to perform the measurement once.
NOTE
Power vs Time measurement is set in the Single sweep mode. Because
of the switching of the Preamp state from On to Off, performing Power
vs Time measurements in the Continuous sweep mode is not
recommended.
After you change the parameters, press
Restart
or
Single
to perform the
measurement again.
Step 9.
Press
Meas Setup
to check
the keys available to change the measurement
parameters from the default condition.
• To extend the number of timeslots to be measured, press
Meas
Interval
and enter the number of timeslots. DwPTS or UpPTS will be
counted as a separate timeslot. The start timeslots is determined by
Analysis Timeslot
.
• To make an averaged measurement, press
Avg/Hold Num
to toggle
the state to
On
and enter the number of averages. Each single
measurement will perform the averages twice.
• To select the averaging algorithm, toggle the
Avg Mode
key between
Exp
and
Repeat
. A Repeat averaged measurement is faster than an
Exponential averaged measurement.
• Press
IF Gain
,
Low Gain
to measure large signals. Option
High Gain
allows better noise level measurements.
Summary of Contents for N9010A
Page 4: ......
Page 7: ...Contents 7 Waveform Signal Envelope Views of I only or Q only 106...
Page 8: ...8 Contents...
Page 12: ...12 Chapter1 Making TD SCDMA with HSPA 8PSK Measurements Setting Up and Making a Measurement...
Page 25: ...Chapter 3 25 ACP Measurements Measurement Procedure Messages Guide...
Page 28: ...28 Chapter3 ACP Measurements Measurement Results...
Page 44: ...44 Chapter5 Spectrum Emission Mask Measurements Troubleshooting Hints...
Page 64: ...64 Chapter8 Power Statistics CCDF Measurements Troubleshooting Hints...
Page 94: ...94 Chapter12 Monitor Spectrum Measurements Measurement Results...