background image

   

4

                                                                                                                              

                            

N5101-90001  

System Requirements

PC Requirements

Requirements for all applications:

You must be able to log on to your PC using an account with administrative privileges.

The PC and all signal sources must be connected via LAN or GPIB.

Available PCI slot(s) must meet the 2.2 PCI/ISA (or later) specifications (see the bottom of 

page 13

).

Not all computer cases are PCI or ISA compliant. PCI compliant computer cases accommodate the N5101A PCI 
card with the metal extender, thus enabling both ends to be restrained. For ISA compliant computer cases, an ISA 
retainer (included) must be attached to the N5101A PCI card metal extender to enable the card to fit into the ISA 
slots. To avoid reliability issues, the N5101A PCI card must be restrained on both ends. Refer to 

page 6

 fo

installation instructions.

Application-specific requirements:

Table  2 

N5110A Baseband Studio for Waveform Streaming

Streaming Rate

Slow (

5 MSa/s)

Medium (

20 MSa/s)

Fast (40 MSa/s)

Processor

Pentium

 4, 2 GHz or greater

Pentium 4, 2 GHz or greater

Pentium 4, 2 GHz or greater

Front Side Bus

400 MHz

533 MHz

533 MHz

Memory 
(Size, Type)

512 MB, PC2100

1 GB, PC2700

2 GB, PC2700

Available 
PCI Slots

1: 32 bit/33 MHz and 1 additional 
PCI slot opening

1: 64 bit/66 MHz and 1 additional 
PCI slot opening

1: 64 bit/66 MHz or 1: 64 bit/133 
MHz

a

 and 1 additional PCI slot 

opening

a. Required for the RAID Controller

HDD 
Controller

Generic IDE

Ultra 160 SCSI RAID Controller

Ultra 320 SCSI RAID Controller

Hard Disks

1: Ultra ATA (7200 RPM)

2: Ultra 160 SCSI (10K RPM)

5: Ultra 320 SCSI (15K RPM)

HDD 
Configuration

Single Drive with OS + Data

Dual Drive with OS + Data

Dedicated OS Drive, Data on 
RAID

Operating 
System

Windows

 2000 Professional, 

SP 3

Windows 2000 Professional, SP 3

Windows 2000 Professional, SP 3

Example

HP XW4100

HP XW8000

HP XW8000 w/add-on HDDs

Summary of Contents for N5101A

Page 1: ...internal PCI card hardware see page 6 for external cabling see page 8 4 Install the Baseband Studio PCI card driver see page 9 After the PCI card installation is complete the procedure directs you to...

Page 2: ...06 Replaceable Parts of GPIO Bracket SMB to MCX Cable P N 8121 0655 Ribbon Cable Assembly P N N5101 60004 7 PCI card ISA Retainer Screws Retainer P N 1400 3295 Screws P N 0624 0858 2 each 4 SMB to SMB...

Page 3: ...quire a license file to be fully functional The entitlement certificate shipped with your application purchase lists the products purchased and has two of the four numbers required to obtain the licen...

Page 4: ...Application specific requirements Table 2 N5110A Baseband Studio for Waveform Streaming Streaming Rate Slow 5 MSa s Medium 20 MSa s Fast 40 MSa s Processor Pentium 4 2 GHz or greater Pentium 4 2 GHz o...

Page 5: ...Dual Channel Configuration Two 32 bit 33 MHz and two additional PCI slot openings Operating System Windows XP Professional SP 1 or greater or Windows 2000 Professional SP 3 or greater Table 5 Require...

Page 6: ...the GPIO bracket ribbon cable to J3 on the PCI card The remaining cables can be connected as shown either before or after you install the PCI card in the computer 2 For PCI compliant computer cases i...

Page 7: ...shielding using the two screws provided See the illustration below The extender will slip into the guides at the front of the ISA compliant PC case as shown in the illustration above 5 Secure the rear...

Page 8: ...s to ensure that they are clean 2 Connect a digital bus cable between each N5101A Baseband Studio PCI card and a source or N5102A Baseband Studio digital signal interface module connecting the end of...

Page 9: ...seband Studio PCI Card page click the Baseband Studio PCI Card Driver link and follow the download instructions Application Software To install the Baseband Studio application software refer to the Ag...

Page 10: ...Software CD 2 Insert the software CD into your PC s CD ROM drive 3 In the Found New Hardware wizard click Next Follow the instructions in this wizard and accept the driver N5101A inf If the wizard doe...

Page 11: ...When you initially run a Baseband Studio application it looks for the required license file Configuring the Vector Signal Generator Using the LAN Interface Direct LAN Connection between PC and Vector...

Page 12: ...ice 7 Enter the signal source s IP address a device name is not required 8 Click OK OK OK OK to close IO Config windows 9 As verification run the Agilent IO Libraries Visa assistant program Start Prog...

Page 13: ...lect Properties In the Device status area you should see the message This device is working properly If not the N5101A Baseband Studio PCI card is probably not seated properly in the PC N5101A PCI Car...

Page 14: ...internally using three MCX to MCX cables Agilent part number 8121 0620 These cables are not provided with the PCI card The cables have MCX male connectors on both ends They are connected as shown belo...

Page 15: ...to contact your local Agilent office http www agilent com find assist If you do not have access to the Internet please contact your field engineer NOTE In any correspondence or telephone conversation...

Page 16: ...ent web site search tool to search for the document part number Agilent N5101A Baseband Studio PCI Card Memory Upgrade Installation Note Agilent part number N5101 90003 Agilent Technologies Software I...

Reviews: