BERT connected to your device:
• There is no clock signal from your device.
• Your device is faulty.
DATA LOSS
This indicator turns red when no data signal is detected at the ED Data In port.
BERT connected looped back or to your device:
• The PG data output is off or not connected.
• There is no connection to the ED data input.
• The 0/1 threshold is not in the eye limits of the incoming data signal. Use
Auto
Align
or select
Avg 0/1 Threshold
.
• Your cables are faulty.
BERT connected to your device:
• There is no data signal from your device.
• Your device is faulty.
SYNC LOSS
This indicator turns red when the measured BER is higher than the sync threshold.
BERT connected looped back or to your device:
• The sampling point is incorrect. Use
Auto Align
.
• The data pattern is inverted. Toggle
Data Inverted
or use
Auto Align
.
• The ED pattern does not match the incoming data pattern. Make the ED track
the PG pattern, or set ED and PG patterns independently the same.
• Patterns have lost sync in manual sync mode. Use
Auto Align
,
Sync Now
, or
select
Auto Sync
mode.
BERT connected to your device:
• The data eye is very small. If
Auto Align
does not correct sync loss, set the 0/1
threshold manually.
• Your device has inverted the data pattern. Toggle
Data Inverted
or use
Auto
Align
.
• Your device has changed the data pattern. Set the ED and PG patterns
separately.
• If the fundamental BER of your device is higher than the sync threshold BER,
you can select a higher sync threshold BER.
Solving Problems
9
Agilent J-BERT N4903B High-Performance Serial BERT
471
Summary of Contents for J-BERT N4903B
Page 1: ...S Agilent J BERT N4903B High Performance Serial BERT User Guide s Agilent Technologies ...
Page 10: ...10 Agilent J BERT N4903B High Performance Serial BERT ...
Page 36: ...1 Planning the Test 36 Agilent J BERT N4903B High Performance Serial BERT ...
Page 60: ...2 Setting up External Instrument s 60 Agilent J BERT N4903B High Performance Serial BERT ...
Page 120: ...3 Setting up Patterns 120 Agilent J BERT N4903B High Performance Serial BERT ...
Page 360: ...6 Advanced Analysis 360 Agilent J BERT N4903B High Performance Serial BERT ...
Page 468: ...8 Jitter Tolerance Tests 468 Agilent J BERT N4903B High Performance Serial BERT ...
Page 524: ...9 Solving Problems 524 Agilent J BERT N4903B High Performance Serial BERT ...
Page 566: ...10 Customizing the Instrument 566 Agilent J BERT N4903B High Performance Serial BERT ...