The other windows have the shapes illustrated in the figure below:
You can see from the figure that the Blackman window is the strongest filter.
The windows are based on the following formulas:
N O T E
In case of leakage, FFT windows improve the spectral resolution. FFT windows
generally reduce the measured spectral power.
For an introduction to FFT windows see
“Leakage and Windowing” on page 349
Pass/Fail Tab
The
Pass/Fail
tab of the
Properties
dialog box allows you to specify the criteria
to decide whether the DUT passes or fails the test. You can change pass/fail
criteria without rerunning a test. The software only uses the criteria to rate the
results of a measurement.
Advanced Analysis
6
Agilent J-BERT N4903B High-Performance Serial BERT
355