Burst mode is disabled.
•
Error Location Capture cannot be used.
•
The function
Error Detector Pattern tracks the Pattern Generator Pattern
is
disabled. This function is not re-enabled when the BRM is
terminated.
•
BRM does not work above 11.5 Gb/s when the CDR is enabled. CDR
> 11.5 GHz is only available with the full range CDR (N4903A SER
No. DE46Bxxxx or Option CTR/Upgrade UTR).
BRM indicators:
•
The mode is indicated in the status panel and in the BER Bar.
•
The mode is indicated in all screen dumps and log files.
•
The Measurement User Interface shows when this mode is used.
Sampling Point Setup - Procedures
In most cases you will set up the sampling point automatically. Even if
you wish to make some manual adjustments, it is recommended to start
with automatically aligning the sampling point.
N O T E
Before adjusting the sampling point, make sure the pattern synchronization mode
is set up properly. See
“Pattern Synchronization - Procedures” on page 150
details.
How to Set the Optimum Sampling Point Automatically
1
Click the
Sampling Point Setup
icon in the
ED Setup
menu.
2
Select an appropriate BER threshold from the
BER Threshold
list.
3
Press
Auto Align
to automatically set the optimum sampling point.
You can stop the search for the optimum sampling point at any time by
pressing
Cancel
.
How to Adjust the Data Input Delay
1
Press the
Sampling Point Setup
icon in the
ED Setup
menu.
2
Select the
Avg. 0/1 Threshold
checkbox to use a good start point on the
vertical voltage axis.
Setting up the Error Detector
4
Agilent J-BERT N4903 High-Performance Serial BERT
129
Summary of Contents for J-BERT N4903
Page 1: ...S Agilent J BERT N4903 High Performance Serial BERT User Guide s Agilent Technologies...
Page 68: ...2 Setting up Patterns 68 Agilent J BERT N4903 High Performance Serial BERT...
Page 158: ...4 Setting up the Error Detector 158 Agilent J BERT N4903 High Performance Serial BERT...
Page 314: ...6 Evaluating Results 314 Agilent J BERT N4903 High Performance Serial BERT...
Page 374: ...7 Jitter Tolerance Tests 374 Agilent J BERT N4903 High Performance Serial BERT...
Page 394: ...8 Solving Problems 394 Agilent J BERT N4903 High Performance Serial BERT...
Page 434: ...Index 434 Agilent J BERT N4903 High Performance Serial BERT...