![Agilent Technologies J-BERT N4903 User Manual Download Page 107](http://html1.mh-extra.com/html/agilent-technologies/j-bert-n4903/j-bert-n4903_user-manual_2868694107.webp)
Data Out
A A A A A A A A B B B B A
A0
A0
B0
A0
A A A
Insert B pressed
Aux In
In this section you can enable the Aux In port to control the output
pattern. Aux In can receive signals that control alternate patterns or
blank the output.
The signals received at this port must be TTL-compatible. The
granularity for signals at this port is 512 bits.
The following options are available for
Aux In
:
•
Disable
With this option selected, the signal at the Aux In port will be
ignored.
•
Level Sensitive
– If
Aux In
is logic high, pattern B is sent.
– If
Aux In
is logic low, pattern A is sent.
Aux In
Data Out
A
A
B
A
B
B
B
•
Edge Sensitive
Pattern A is sent out until a rising edge at Aux In is detected. Then,
at the next complete repetition of pattern A, a single occurrence of
pattern B is inserted into the output.
Aux In
Data Out
A
A
B
A
B
A
A
•
Output Blanking
Pattern A is sent when the signal at Aux In is low. Pattern B is not
sent in this mode.
Data Out
Aux In
A
A
A
A
If
Aux In
is pulled to logic high and a standard pattern is selected, no
output pattern will be sent.
Setting up the Pattern Generator
3
Agilent J-BERT N4903 High-Performance Serial BERT
107
Summary of Contents for J-BERT N4903
Page 1: ...S Agilent J BERT N4903 High Performance Serial BERT User Guide s Agilent Technologies...
Page 68: ...2 Setting up Patterns 68 Agilent J BERT N4903 High Performance Serial BERT...
Page 158: ...4 Setting up the Error Detector 158 Agilent J BERT N4903 High Performance Serial BERT...
Page 314: ...6 Evaluating Results 314 Agilent J BERT N4903 High Performance Serial BERT...
Page 374: ...7 Jitter Tolerance Tests 374 Agilent J BERT N4903 High Performance Serial BERT...
Page 394: ...8 Solving Problems 394 Agilent J BERT N4903 High Performance Serial BERT...
Page 434: ...Index 434 Agilent J BERT N4903 High Performance Serial BERT...