Triggering the Oscilloscope
4
6000 Series Oscilloscope User’s Guide
151
< qualifier time set softkey
•
When the less than (
<
) qualifier is selected, the Entry knob
sets the oscilloscope to trigger on a pattern duration less
than the time value displayed on the softkey.
•
When the within time range (
><
) qualifier is selected, the
Entry knob sets the upper time range value.
•
When the out of time range (
<>
) qualifier is selected, the
Entry knob sets the lower time range value.
> qualifier time set softkey
•
When the greater than (
>
) qualifier is selected, the Entry
knob sets the oscilloscope to trigger on a pattern duration
greater than the time value displayed on the softkey.
•
When the within time range (
><
) qualifier is selected, the
Entry knob sets the lower time range value.
•
When the out of time range (
<>
) qualifier is selected, the
Entry knob sets the upper time range value.
•
When
Timeout
qualifier is selected, the Entry knob sets the
timeout value.
When the duration trigger occurs
The timer starts on the last edge that makes the pattern (logical AND) true. The
trigger will occur on the first edge that makes the pattern false if the time
qualifier criteria of the pattern has been met, except in Timeout mode. In
Timeout, the trigger occurs when the timeout value is reached while the pattern
is true.
Summary of Contents for InfiniiVision DSO6014L
Page 2: ...Agilent Technologies Agilent 6000 Series Oscilloscopes User s Guide...
Page 59: ...58 6000 Series Oscilloscope User s Guide 1 Getting Started...
Page 109: ...108 6000 Series Oscilloscope User s Guide 2 Front Panel Controls...
Page 125: ...124 6000 Series Oscilloscope User s Guide 3 Viewing and Measuring Digital Signals...
Page 251: ...250 6000 Series Oscilloscope User s Guide 5 Making Measurements...
Page 287: ...286 6000 Series Oscilloscope User s Guide 6 Displaying Data Interpreting Decoded LIN Data...
Page 321: ...320 6000 Series Oscilloscope User s Guide 7 Saving and Printing Data...
Page 370: ......