Commands by Subsystem
5
Agilent InfiniiVision 7000A Series Oscilloscopes Programmer's Guide
395
:POD<n>:THReshold
Command Syntax
:POD<n>:THReshold <type>[<suffix>]
<n> ::= An integer, 1 or 2, is attached as a suffix to the command and
defines the group of channels that are affected by the command.
<type> ::= {CMOS | ECL | TTL | <user defined value>}
<user defined value> ::= -8.00 to +8.00 in NR3 format
<suffix> ::= {V | mV | uV}
POD1 ::= D0-D7
POD2 ::= D8-D15
TTL ::= 1.4V
CMOS ::= 2.5V
ECL ::= -1.3V
The :POD<n>:THReshold command sets the threshold for the specified
group of channels. The threshold is used for triggering purposes and for
displaying the digital data as high (above the threshold) or low (below the
threshold).
Query Syntax
:POD<n>:THReshold?
The :POD<n>:THReshold? query returns the threshold value for the
specified group of channels.
Return Format
<threshold><NL>
<threshold> ::= Floating point number in NR3 format
See Also
•
"Introduction to :POD<n> Commands"
•
•
Example Code
' THRESHOLD - This command is used to set the voltage threshold for
' the waveforms.
There are three preset values (TTL, CMOS, and ECL)
' and you can also set a user-defined threshold value between
' -8.0 volts and +8.0 volts.
'
' In this example, we set channels 0-7 to CMOS, then set channels
' 8-15 to a user-defined 2.0 volts, and then set the external trigger
' to TTL.
Of course, you only need to set the thresholds for the
' channels you will be using in your program.
N O T E
This command is only valid for the MSO models.
Summary of Contents for InfiniiVision 7000A Series
Page 1: ...Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide...
Page 34: ...34 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 1 What s New...
Page 44: ...44 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 2 Setting Up...
Page 58: ...58 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 3 Getting Started...
Page 750: ...750 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 8 Error Messages...
Page 922: ...922 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide Index...