:SBUS<n> Commands
26
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
681
:SBUS<n>:IIC:TRIGger[:TYPE]
Command Syntax
:SBUS<n>:IIC:TRIGger[:TYPE] <value>
<value> ::= {STARt | STOP | READ7 | READEprom | WRITe7 | WRITe10
| NACKnowledge | ANACk | R7Data2 | W7Data2 | RESTart}
The :SBUS<n>:IIC:TRIGger[:TYPE] command sets the IIC trigger type:
•
STARt — Start condition.
•
STOP — Stop condition.
•
READ7 — 7- bit address frame containing
(Start:Address7:Read:Ack:Data). The value READ is also accepted for
READ7.
•
R7Data2 — 7- bit address frame containing
(Start:Address7:Read:Ack:Data:Ack:Data2).
•
READEprom — EEPROM data read.
•
WRITe7 — 7- bit address frame containing
(Start:Address7:Write:Ack:Data). The value WRITe is also accepted for
WRITe7.
•
W7Data2 — 7- bit address frame containing
(Start:Address7:Write:Ack:Data:Ack:Data2).
•
WRITe10 — 10- bit address frame containing (Start:Address
byte1:Write:Ack:Address byte 2:Data).
•
NACKnowledge — Missing acknowledge.
•
ANACk — Address with no acknowledge.
•
RESTart — Another start condition occurs before a stop condition.
Query Syntax
:SBUS<n>:IIC:TRIGger[:TYPE]?
The :SBUS<n>:IIC:TRIGger[:TYPE]? query returns the current IIC trigger
type value.
Return Format
<value><NL>
<value> ::= {STAR | STOP | READ7 | READE | WRIT7 | WRIT10 | NACK | ANAC
| R7D2 | W7D2 | REST}
See Also
•
"Introduction to :TRIGger Commands"
•
N O T E
The short form of READ7 (READ7), READEprom (READE), WRITe7 (WRIT7), and WRITe10
(WRIT10) do not follow the defined Long Form to Short Form Truncation Rules (see
Summary of Contents for InfiniiVision 3000 X-Series
Page 1: ...s1 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide...
Page 30: ...30 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide...
Page 54: ...54 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 2 Setting Up...
Page 68: ...68 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 3 Getting Started...
Page 218: ...218 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 6 Root Commands...
Page 242: ...242 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands...
Page 280: ...280 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 11 DEMO Commands...
Page 288: ...288 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 12 DIGital d Commands...
Page 340: ...340 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 15 FUNCtion Commands...
Page 358: ...358 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 16 HARDcopy Commands...
Page 378: ...378 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 18 MARKer Commands...
Page 446: ...446 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 19 MEASure Commands...
Page 564: ...564 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 23 POWer Commands...
Page 842: ...842 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 29 TIMebase Commands...
Page 1054: ...1054 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 35 Error Messages...
Page 1076: ...1076 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 36 Status Reporting...
Page 1232: ...1232 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide Index...