![Agilent Technologies InfiniiVision 3000 X-Series Programmer'S Manual Download Page 663](http://html1.mh-extra.com/html/agilent-technologies/infiniivision-3000-x-series/infiniivision-3000-x-series_programmers-manual_2868684663.webp)
:SBUS<n> Commands
26
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
663
:SBUS<n>:I2S:TRIGger
Command Syntax
:SBUS<n>:I2S:TRIGger <operator>
<operator> ::= {EQUal | NOTequal | LESSthan | GREaterthan | INRange
| OUTRange | INCReasing | DECReasing}
The :SBUS<n>:I2S:TRIGger command sets the I2S trigger operator:
•
EQUal— triggers on the specified audio channel's data word when it
equals the specified word.
•
NOTequal — triggers on any word other than the specified word.
•
LESSthan — triggers when the channel's data word is less than the
specified value.
•
GREaterthan — triggers when the channel's data word is greater than
the specified value.
•
INRange — enter upper and lower values to specify the range in which
to trigger.
•
OUTRange — enter upper and lower values to specify range in which
trigger will not occur.
•
INCReasing — triggers when the data value makes a certain increase
over time and the specified value is met or exceeded. Use the
:SBUS<n>:I2S:TRIGger:RANGe command to set "Trigger" and "Armed"
values. The "Trigger" value is the value that must be met or exceeded to
cause the trigger. The "Armed" value is the value the data must go
below in order to re- arm the oscilloscope (ready it to trigger again).
•
DECReasing — similar to INCReasing except the trigger occurs on a
certain descrease over time and the "Trigger" data value is less than the
"Armed" data value.
Query Syntax
:SBUS<n>:I2S:TRIGger?
The :SBUS<n>:I2S:TRIGger? query returns the current I2S trigger operator.
Return Format
<operator><NL>
<operator> ::= {EQU | NOT | LESS | GRE | INR | OUTR | INCR | DECR}
"Trigger" value
Trigger
Trigger
No trigger
"Armed" value
Summary of Contents for InfiniiVision 3000 X-Series
Page 1: ...s1 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide...
Page 30: ...30 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide...
Page 54: ...54 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 2 Setting Up...
Page 68: ...68 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 3 Getting Started...
Page 218: ...218 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 6 Root Commands...
Page 242: ...242 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands...
Page 280: ...280 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 11 DEMO Commands...
Page 288: ...288 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 12 DIGital d Commands...
Page 340: ...340 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 15 FUNCtion Commands...
Page 358: ...358 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 16 HARDcopy Commands...
Page 378: ...378 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 18 MARKer Commands...
Page 446: ...446 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 19 MEASure Commands...
Page 564: ...564 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 23 POWer Commands...
Page 842: ...842 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 29 TIMebase Commands...
Page 1054: ...1054 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 35 Error Messages...
Page 1076: ...1076 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide 36 Status Reporting...
Page 1232: ...1232 Agilent InfiniiVision 3000 X Series Oscilloscopes Programmer s Guide Index...