5-62
N9360A Multi UE Tester GSM Programming Manual
5
Programming Command Reference
Power Control Level
CONFigure:CONDition:PLEVel:HIGH <int>
CONFigure:CONDition:PLEVel:HIGH?
CONFigure:CONDition:PLEVel:MEDium <int>
CONFigure:CONDition:PLEVel:MEDium?
CONFigure:CONDition:PLEVel:LOW <int>
CONFigure:CONDition:PLEVel:LOW?
CONFigure:CONDition:PLEVel:MAN <int>
CONFigure:CONDition:PLEVel:MAN?
These commands set a value of Power Control Level (PWR
CNTL) to each of the High, Medium and Low ranges for
Automatic Test and Manual Test, for each radio system set by
the
command described on
. The
allowable range and preset values are as follows.
This query command returns the set Power Control Level with
integer. The range of the value is same as that of the command
parameter.
Table 5-11 Power Control Level Allowable Range and Preset Value
RFORmat
Allowable Range
Preset Value
AUTO
*
MANUAL
GSM850
2 (+39 dBm) to 19 (+5 dBm)
5, 10, 15
5
GSM900
2 (+39 dBm) to 19 (+5 dBm)
5, 10, 15
5
DCS1800
0 (+30 dBm) to 15 (+0 dBm), or
29 (+36 dBm) to 31 (+32 dBm)
0, 5, 10
0
PCS1900
0 (+30 dBm) to 15 (+0 dBm), or
29 (+36 dBm) to 31 (+32 dBm)
0, 5, 10
0
* Values are in the order of High, Medium, and Low ranges.